Skip to content

What are you looking for?


You may also like

1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module
1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module
1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module
1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module

1771-IAD | Allen Bradley PLC-5 Digital AC/DC Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1771-IAD

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1771-IAD is a digital input module designed for the PLC-5 system. It supports both AC and DC signals within the 79–138 V operating range, making it versatile for industrial automation applications. With 16 input channels and reliable signal delay performance, this module is engineered for consistent operation in demanding environments.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Category: PLCs

  • Product Line: PLC-5

  • Part Number: 1771-IAD

  • Weight: 1.00 lbs (0.45 kg)

  • Module Type: Digital AC/DC Input Module

  • Number of Inputs: 16 channels

  • DC Operating Voltage: 79–138 VDC

  • AC Operating Voltage: 79–138 VAC

  • Voltage Category: 120 V AC/DC

  • Typical DC Signal Delay (On): 3 ms (+/- 0.1) or 10 ms (+/- 1)

  • Typical DC Signal Delay (Off): 25 ms (+/- 5)

  • Typical AC Signal Delay (On): 5 ms (+/- 3)

  • Typical AC Signal Delay (Off): 25 ms (+/- 5)

  • Max AC Off-State Current: 2.8 mA

  • Max DC Off-State Current: Not applicable

  • Backplane Current: 195 mA

  • Wiring Arm: 1771-WH

  • Module Location: Compatible with 1771-A1B, A2B, A3B, A3B1, A4B, 1771-AM1, and AM2 chassis

Application Scenarios

  • Designed for PLC-5 systems requiring AC/DC input monitoring

  • Suitable for process control, manufacturing, and automation environments

  • Provides reliable input signal detection for mixed voltage applications

FAQ

Q: How many input channels does the 1771-IAD provide?  A: It supports 16 input channels.

Q: What is the operating voltage range?  A: The module operates between 79–138 VAC or VDC.

Q: Which wiring arm is required?  A: The compatible wiring arm is 1771-WH.

Comparison with Similar Models

  • 1771-IAD: AC/DC input, 16 channels, 120 V category

  • 1771-IA: AC-only input, 16 channels, lower cost option

  • 1771-ID: DC-only input, 16 channels, optimized for DC applications

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more