Skip to content

What are you looking for?


You may also like

P0926TM Foxboro Remote Fieldbus Cable AssemblyP0926TM Foxboro Remote Fieldbus Cable AssemblyP0926TM Foxboro Remote Fieldbus Cable Assembly
P0926TM Foxboro Remote Fieldbus Cable Assembly
P0926TM Foxboro Remote Fieldbus Cable Assembly
P0926TM Foxboro Remote Fieldbus Cable Assembly

P0926TM Foxboro Remote Fieldbus Cable Assembly


Only 10 left - Selling fast

PRODUCT SKU : P0926TM

PRODUCT TYPE : Cable Assemblies

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for remote Fieldbus backbone signal transfer and power interconnectivity in Foxboro I/A Series DCS networks, the Foxboro P0926TM-8FT (P0926TM Cable Assembly) provides direct physical/electrical execution. It links Field Bus Modules (FBM) to centralized control processors across distributed architecture backplanes. The factory-terminated assembly conveys dual-path communication frames and high-density power profiles without inline signal amplification hardware.

Hardware Specifications

Parameter Specification
Model P0926TM-8FT
Brand Foxboro
Origin USA
Weight 1.28 kg (2.82 lbs)
Dimensions 8 ft length (2.44 m)
Operating Temp -20 to +70 deg C
Power Consumption Passive (0 W)
Cable Structure Shielded Twisted-Pair (STP)
Rated Voltage 120-240 VAC / 125 VDC

DCS Fieldbus Protocol and Channel-to-Channel Isolation

The Foxboro P0926TM assembly integrates braided shielding over twisted-pair conductors to enforce channel-to-channel isolation across long-distance communication runs. Operating within Foxboro I/A Series architectures, the cable limits cross-talk and preserves differential signal propagation in environments with severe electromagnetic interference (EMI). The assembly maintains strict impedance tolerances to support 4-20 mA HART loop protocol pass-through and fieldbus register polling across high-density I/O node clusters.

Frequently Asked Questions

Q: What is the primary purpose of the factory termination on the P0926TM cable assembly?

A: Factory-molded connectors ensure precise impedance matching at the terminal interfaces, eliminating field soldering errors and protecting signal conductor integrity against ambient moisture and vibration.

Q: Can the P0926TM cable be routed alongside high-voltage AC motor lines inside control cabinets?

A: Standard installation practices mandate physical segregation. Although the cable includes high-density braid shielding for EMI suppression, running fieldbus cables in dedicated low-voltage instrument raceways prevents inductive transient coupling.

Field Installation Guidelines

  1. Inspect the connector pins and locking keyways on both cable ends before insertion into the FBM baseplate receptacles.
  2. Route the 8 ft assembly through designated instrument cable trays, maintaining a minimum static bend radius of 75 mm.
  3. Fully engage the connector shell latches into the fieldbus port headers until tactile engagement is achieved.
  4. Verify that the cable drain wire terminates to the cabinet primary Earth ground bus to maintain shield grounding continuity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more