You may also like

Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)
Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)
Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)
Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)

Honeywell MU-KFTA30 51197595-300 FTA Interconnection Cable (30m)


Only 10 left - Selling fast

PRODUCT SKU : MU-KFTA30

PRODUCT TYPE : FTA Interconnection Cable

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MU-KFTA30 (Part Number: 51197595-300 / 51201420-030) serves as a high-reliability Field Termination Assembly (FTA) interconnection link within the Honeywell TDC 3000 and TotalPlant Solution (TPS) architectures. This 30-meter cable facilitates the critical data path between I/O processors and field termination boards. We provide this component as 100% Brand New Original equipment to ensure millivolt-precision signal accuracy and long-term network stability.

Technical Specifications

The MU-KFTA30 is engineered to maintain low impedance over extended lengths for critical process control:

Feature Specification Details
Model Number MU-KFTA30
Part Number 51197595-300 (or 51201420-030)
Manufacturer Honeywell (USA)
Length 30 Meters (Approx. 98.4 ft)
Interface Type RS-485 / Analog Signal Support
Input Voltage 24 VDC Nominal
Wire Gauge High-Flexibility Industrial Grade
Operating Temp -10°C to +60°C
Condition 100% Brand New Original

Engineering Advantages

  • Precision Signal Integrity: The 30-meter MU-KFTA30 maintains low attenuation for both digital and 4-20mA analog signals. This ensures that field data reaches the controller without the voltage drops common in non-proprietary cabling.

  • Built-in Fault Mitigation: The cable construction supports Honeywell’s system-level diagnostics, enabling the controller to detect open-circuit or short-circuit conditions at the termination level.

  • Simplified Long-Distance Routing: At 30 meters, this cable allows engineers to centralize controllers in climate-controlled environments while placing Field Termination Assemblies closer to the physical process, reducing local wiring costs.

  • EMI Shielding: Advanced internal shielding protects low-level control signals from the "noise" generated by nearby variable frequency drives (VFDs) and heavy machinery commonly found in industrial plants.

FAQs

  • Can I use the MU-KFTA30 with any Honeywell FTA board?

    This cable specifically fits the MU-series and MC-series Field Termination Assemblies used in TDC 3000 and TPS systems. Always check your FTA's pin configuration to ensure a match with the MU-KFTA30's connector standard.

  • Is this cable rated for outdoor use?

    The MU-KFTA30 is designed for industrial indoor environments. If routing between buildings or in outdoor trays, we recommend using rigid conduit to protect the jacket from UV degradation and mechanical stress.

  • Does the cable come pre-terminated?

    Yes. The cable features factory-molded connectors on both ends. This "Plug-and-Play" design eliminates the high failure rate associated with hand-crimped field connections in high-vibration areas.

  • How does the length affect signal delay?

    Honeywell engineers the TDC 3000 communication protocols to account for the propagation delay of 30-meter links. Using this original cable ensures your system timing remains within factory-specified tolerances.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more