Overview

The 8C-TPOXA1 is a coated Input/Output Terminal Assembly (IOTA PWA) developed by Honeywell for the Series 8 platform. It provides a reliable communication interface between field devices and the control system, ensuring stable signal transfer and redundancy support for mission-critical automation environments.

Features

  • Redundant Configuration: Supports dual IOTA setup with interconnecting sync cable for fault-tolerant operation.

  • High Durability: Coated surface protects against humidity, dust, and corrosive industrial conditions.

  • Versatile Connectivity: Equipped with FTE A (yellow), FTE B (green), DB9F, and redundancy CAT5e connectors.

  • Simplified Installation: Designed for easy mounting and wiring within Honeywell Series 8 racks.

  • Certifications: UL, CE, and RoHS compliant for safety and environmental assurance.

  • Stable Communication: Ensures consistent data transmission across distributed control networks.

Technical Specifications

  • Model Number: 8C-TPOXA1

  • Type: IOTA PWA (Input/Output Terminal Assembly Printed Wiring Assembly)

  • Voltage Rating: 24 VDC

  • Module Current Rating: 430 mA

  • Operating Temperature: 0°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Connectors:

    • FTE A (yellow) and FTE B (green) CAT5e connectors

    • DB9F connector for DP networks

    • CAT5e connector for redundancy synchronization

  • Power Consumption: 5 W (typical)

  • Redundancy: Supported via dual IOTA configuration with interconnecting sync cable

  • Country of Origin: United States

Applications

Ideal for industrial control systems requiring high communication reliability, including refineries, chemical plants, and process automation facilities using Honeywell Experion PKS and Series 8 controllers.

FAQ

Q: Can this module be used with redundant configurations?
A: Yes, the 8C-TPOXA1 supports redundant operation when paired with a second IOTA and sync cable.

Q: What types of network connections does this module support?
A: It includes CAT5e and DB9F interfaces for FTE, DP, and redundancy synchronization links.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more