Skip to content

What are you looking for?


You may also like

BACHMANN ACR222/2 Axis Controller ModuleBACHMANN ACR222/2 Axis Controller ModuleBACHMANN ACR222/2 Axis Controller Module
BACHMANN ACR222/2 Axis Controller Module
BACHMANN ACR222/2 Axis Controller Module
BACHMANN ACR222/2 Axis Controller Module

BACHMANN ACR222/2 Axis Controller Module


Only 10 left - Selling fast

PRODUCT SKU : ACR222/2

PRODUCT TYPE : Axis Controller Modules

PRODUCT VENDOR : Bachmann


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed motion control in M1 automation platforms, the BACHMANN ACR222/2 (ACR222/2 Axis Controller Module) provides direct physical/electrical execution of stepper motor driving and incremental encoder signal processing.

Hardware Specifications

Parameter Specification
Model ACR222/2
Brand BACHMANN
Origin Austria
Weight 0.28 kg
Dimensions 102 mm x 12 mm x 130 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption 4.0 W
Stepper Interfaces 2 channels, up to 150 kHz
Encoder Interfaces 2 channels, up to 1 MHz
Digital Inputs Home, Abort, 2 Limit switches per channel
Profile Types Linear, sin2, parabolic

Profinet / EtherNet/IP Deterministic Networks

The ACR222/2 integrates into the M1 backplane architecture to ensure synchronization between motion profiles and system-level bus communication. The module supports deterministic network connectivity, allowing for real-time adjustments of velocity profiles via the controller CPU. I/O density scaling is managed through the M1 modular backplane, enabling the expansion of axis control nodes without degrading the bus communication velocity. Firmware flash compatibility is supported, ensuring the motion control algorithms, including the two-step linear speed profiles, can be updated to meet specific mechanical kinematics requirements.

Frequently Asked Questions

Q: Can the ACR222/2 provide power directly to the connected incremental encoders?

A: Yes, the module provides an integrated encoder power supply directly through the front-panel connectors to simplify field wiring.

Q: What is the maximum step frequency supported for the stepper motor output stages?

A: The module supports stepper frequencies up to 150 kHz per interface.

Q: Does the module perform hardware-level monitoring of the connected motor stages?

A: Yes, the module includes monitoring circuitry for the external supplying voltage and supports physical limit switch inputs to ensure operation within configured mechanical boundaries.

Field Installation Guidelines

  1. Connector Wiring: Utilize shielded twisted-pair cables for both encoder feedback and stepper motor signals. Connect cable shields to the system functional earth (FE) terminal to prevent electrical noise interference at the 1 MHz frequency range.
  2. Signal Segregation: Route high-frequency stepper motor pulse signals away from sensitive analog input cables and power wiring to mitigate potential cross-talk.
  3. Grounding: Ensure a low-impedance ground connection for the M1 rack to maintain signal integrity for the high-speed pulse outputs.
  4. Switch Configuration: Verify proper installation and NC/NO logic settings for home, abort, and limit switches during initial commissioning to prevent mechanical overtravel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more