Skip to content

What are you looking for?


You may also like

Yokogawa VI701 CENTUM VP Vnet/IP Interface CardYokogawa VI701 CENTUM VP Vnet/IP Interface CardYokogawa VI701 CENTUM VP Vnet/IP Interface Card
Yokogawa VI701 CENTUM VP Vnet/IP Interface Card
Yokogawa VI701 CENTUM VP Vnet/IP Interface Card
Yokogawa VI701 CENTUM VP Vnet/IP Interface Card

Yokogawa VI701 CENTUM VP Vnet/IP Interface Card


Only 10 left - Selling fast

PRODUCT SKU : VI701

PRODUCT TYPE : Interface Card

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa VI701 acts as the high-speed communication gateway for CENTUM VP control systems, facilitating Vnet/IP connectivity via a standard PCI bus architecture. This interface card enables real-time, large-capacity data exchange between Human Interface Stations (HIS), Engineering Stations (ENG), and the control network. By utilizing Gigabit Ethernet technology, the VI701 ensures deterministic communication and low-latency synchronization across the Distributed Control System (DCS).

Technical Specifications

The VI701 integrates robust networking capabilities with standard industrial computer hardware:

Feature Specification
Communication Speed 1000 Mbps Full Duplex
Transmission Standard 1000Base-T compliant
Connection Port RJ45 Connector
Cable Requirement CAT5e (Enhanced Category 5) UTP
Max. Transmission Distance 100 m (to Layer 2 Switch)
PCI Specification Revision 3.0
Bus Width/Frequency 32-bit / 33 MHz
Power Consumption Max. 2.5 A
Dimensions 106.68 mm x 167.64 mm
Weight 0.2 kg
Condition 100% Brand New and Original

Engineering Advantages

  • Gigabit Throughput: The VI701 delivers 1000 Mbps full-duplex throughput. This high bandwidth eliminates data bottlenecks in complex plants with thousands of I/O points, ensuring the operator console updates instantly during process upsets.

  • On-Board Diagnostics: Three dedicated LED indicators (RDY, RCV, SND) provide immediate hardware feedback. The RDY lamp illuminates only after the card passes internal self-diagnostics, while the RCV and SND lamps verify active traffic on the control bus, simplifying field troubleshooting.

  • Standardized Infrastructure: The card utilizes standard CAT5e cabling and RJ45 connectors. This choice reduces installation costs by allowing the use of conventional industrial Ethernet infrastructure while maintaining high-fidelity signal transmission up to 100 meters.

  • Legacy PCI Support: The VI701 complies with PCI Bus Specification 3.0. This allows engineers to sustain or upgrade existing industrial PC stations without requiring a total hardware overhaul, providing a cost-effective path for system expansion.

FAQs

  • Is this Yokogawa VI701 card brand new or a refurbished pull?

    We offer this VI701 exclusively as 100% Brand New and Original equipment. Each card arrives in its anti-static packaging within the original Yokogawa factory box, ensuring peak performance and full manufacturer-rated lifespan.

  • What do the different LED lamps indicate during operation?

    The RDY lamp confirms the card's internal health. The SND lamp flickers when the HIS/ENG sends data to the control network, and the RCV lamp activates upon detecting incoming signals from the Vnet/IP bus. If the RDY lamp remains off, the card has failed its power-on self-test.

  • Does the VI701 require a specific type of Ethernet cable?

    Yes. You must use CAT5e Enhanced Category 5 UTP cable or better to maintain 1000Base-T compliance. Using lower-rated cables will result in packet loss or reduced communication speeds, compromising DCS stability.

  • What is the maximum distance allowed for a direct connection?

    The VI701 supports a maximum cable length of 100 meters between the card's RJ45 port and the Layer 2 switch. For distances exceeding 100 meters, you must implement fiber optic converters or additional industrial switches.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more