Product Overview

The Yokogawa F3LE11-1T serves as the primary gateway for connecting FA-M3 series PLCs to high-speed Ethernet networks. This module facilitates seamless data exchange between the controller and supervisory systems, supporting both 10BASE-T and 100BASE-TX standards. We supply this unit as 100% Brand New and Original, ensuring your automation architecture utilizes the latest factory-standard hardware for remote monitoring and industrial data logging.

Technical Specifications

Feature Details
Network Standards IEEE 802.3 Compliant
Transmission Speed 10 Mbps (10BASE-T) / 100 Mbps (100BASE-TX)
Protocol Stack TCP/IP, SMTP, POP3
Max Segment Length 100 meters
Access Control CSMA/CD
Current Consumption 330 mA maximum
Dimensions 28.9 (W) × 100 (H) × 83.2 (D) mm
Weight 100 g

Engineering Advantages

  • Enhanced Diagnostic Connectivity: The F3LE11-1T integrates SMTP and POP3 protocols, allowing the PLC to send automated email alerts regarding system status or alarm triggers. This functionality eliminates the need for constant manual oversight and speeds up response times for maintenance teams.

  • Dual-Speed Auto-Negotiation: The module supports 10/100 Mbps speeds, allowing it to interface with both legacy industrial hubs and modern high-speed switches. This versatility ensures stable performance regardless of the existing network infrastructure.

  • High-Density Rack Efficiency: With a width of only 28.9 mm and a weight of 100g, this module maintains a low physical footprint. It slides easily into standard FA-M3 PLC racks, preserving valuable slot space for additional I/O or motion control modules.

  • Stable Baseband Transmission: The hardware utilizes baseband transmission and CSMA/CD access control to minimize data collisions. This ensures deterministic communication paths required for real-time remote monitoring and synchronized data logging systems.

FAQs

  • Does this module support fiber optic connections? No, the F3LE11-1T utilizes standard RJ-45 connectors for twisted-pair copper cabling. To transition to fiber, you must use an external media converter or an alternative Yokogawa fiber-specific interface module.

  • How do I configure the email notification feature? You configure the SMTP server settings and recipient addresses within the FA-M3 programming environment. The module then triggers emails based on specific ladder logic conditions or register values defined by the user.

  • Is the F3LE11-1T compatible with all FA-M3 CPU types? The F3LE11-1T works with most standard FA-M3 CPU modules. However, always verify that your specific CPU firmware version supports Ethernet communication functions to ensure full protocol transparency.

  • What is the maximum number of segments allowed in a cascade setup? The module supports up to 2 segments or up to 4 segments depending on your specific network topology and the type of switching equipment used. For maximum stability over 100 meters, we recommend using active industrial switches.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more