Skip to content

What are you looking for?


You may also like

Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)
Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)
Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)
Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)

Yokogawa AFV10D-S41201 Duplicated Field Control Unit (FCU)


Only 10 left - Selling fast

PRODUCT SKU : AFV10D-S41201

PRODUCT TYPE : Field Control Unit

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AFV10D-S41201 serves as the high-performance "brain" of the CENTUM VP Distributed Control System (DCS). As a Duplicated (Duplexed) Field Control Unit, it executes complex regulatory control, sequence logic, and advanced computational functions for mission-critical industrial processes. The "D" prefix signifies its redundant architecture; the unit utilizes two processor modules in a "Hot Standby" configuration. If the primary processor encounters a fault, the secondary unit assumes control in milliseconds, ensuring zero process interruption and maintaining total plant safety.

Condition: 100% Brand New and Original Factory Sealed.

Part Number Breakdown: AFV10D-S41201

Yokogawa utilizes a specific suffix code to define the hardware, power, and networking specifications of the FCU:

  • AFV10D: Duplicated Field Control Unit (for Vnet/IP and FIO).

  • -S: Standard type hardware.

  • 4: Dual-redundant 100-120 V AC Power Supply.

  • 1: 19-inch Rack-mount type.

  • 2: Vnet/IP Interface (Redundant).

  • 0: Always 0.

  • 1: Basic hardware revision for optimized processor stability.

Technical Specifications

The AFV10D-S41201 provides the high-speed processing and robust networking required for modern automation.

  • Processor Type: High-speed RISC processor.

  • Control Network: Vnet/IP (1 Gbps Redundant Ethernet).

  • I/O Bus: FIO (Field Input/Output) bus interface.

  • Memory Protection: Battery-backed RAM for database retention during power loss.

  • Power Supply: 100-120 V AC, 50/60 Hz (Dual-redundant).

  • Mounting: Standard 19-inch rack-mount.

  • Application Capacity: Supports thousands of function blocks (PIDs, Logics, Timers).

Engineering Advantages

  • Seamless Process Continuity: The AFV10D-S41201 synchronizes data between two CPU modules every scan cycle. This "Hot Standby" redundancy eliminates "bumps" in control output during a switchover, protecting sensitive equipment like turbines and reactors.

  • High-Speed Vnet/IP Backbone: Utilizing a 1 Gbps Vnet/IP network, this controller transmits massive amounts of process data to the HMI and other control stations with negligible latency. This high bandwidth is essential for large-scale plants with high tag counts.

  • Robust FIO Integration: This FCU acts as the master for Yokogawa’s FIO (Field I/O) modules (e.g., ADV151, ADV551). The local bus architecture ensures rapid data refresh rates between field sensors and the controller's logic engine.

  • Online Maintenance & Hot-Swapping: All redundant components, including the PW481 power supply units and communication cards, allow for replacement while the plant remains under active control. This capability maximizes plant uptime and simplifies preventive maintenance.

  • Space-Efficient Rack Design: The standard 19-inch form factor integrates easily into existing DCS cabinets. The internal layout prioritizes natural convection cooling, extending the lifespan of the internal electronic components.

FAQs

  • Does this unit include the CP461 CPU modules?

    The AFV10D-S41201 specifies the chassis, power supply, and network interface. While it houses the CPU modules, the specific processors (typically CP461) are often listed as separate line items in a full system configuration.

  • What is the difference between AFV10D and AFV30D?

    The AFV10D is the standard Field Control Unit, whereas the AFV30D offers higher application capacity and faster processing for extremely large or complex control strategies.

  • How often should I replace the backup battery?

    The lithium battery (Part No. S9185FA) preserves the control database during total power failure. We recommend proactive replacement every 3 to 5 years during scheduled plant turnarounds.

  • Can this unit be used with 220V AC?

    No. The "-4" suffix indicates 100-120V AC. For 220-240V AC power environments, the AFV10D-S21201 is the correct model.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




  • 5 stars: 4 (80%)
  • 4 stars: 1 (20%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
A
Aaron

Great experience with this supplier. The FCU integrates well with existing Yokogawa I/O modules, and the system response is fast. Everything matched the specifications provided.

B
Brian

The product itself is excellent—solid build and reliable performance. Setup took a bit longer due to system integration, but that’s expected for this type of equipment. Seller support was helpful.

T
Thomas

We deployed this unit in a petrochemical plant, and performance has been stable since commissioning. Communication over Vnet/IP is fast with no noticeable delay. Good quality and fast delivery.

M
Mark

Very reliable FCU. The hot standby redundancy is impressive and gives us confidence in critical operations. Seller provided quick responses to technical questions. Smooth transaction overall.

J
Jonathan

Excellent condition, exactly as described—factory sealed. We installed it in our CENTUM VP system and the redundant switchover works seamlessly. No interruption during testing. Shipping was fast and well handled.

Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more