Product Description

The AAI543-H00 / K4A00 analog output module from Yokogawa is engineered for precise signal transmission in distributed control systems. Supporting HART-enabled communication, this module provides reliable analog outputs for actuators, valves, and motors, ensuring accurate process control in demanding industrial environments. With redundancy support and high-speed data updates, it is optimized for mission-critical automation.

Technical Specifications

  • Model Number: AAI543-H00 / K4A00

  • Type: Analog Output Module

  • Output Signal: 4–20 mA DC

  • Number of Channels: 16 isolated output channels

  • Communication Protocol: HART-enabled (digital over analog)

  • Load Resistance: 0–750 Ω

  • Circuit-Open Detection: <0.65 mA

  • Accuracy: ±48 μA

  • Data Update Period: 10 ms

  • Temperature Drift: ±16 pA per 10°C change

  • Withstanding Voltage: 1500 V AC between output and system for 1 minute

  • Power Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • External Interface: Pressure clamp terminal, MIL connector, KS cable (for AEA4D board)

  • Dimensions (W × H × D): 3.7 × 13.8 × 12.1 cm

  • Weight: 0.4 kg

  • Redundancy Support: Yes – automatic switch-over in dual configuration

Key Features

  • High Precision: Stable 4–20 mA signal output with low drift

  • Fast Response: 10 ms update cycle for real-time control

  • Redundant Operation: Dual-module support for fail-safe reliability

  • HART Integration: Digital communication over analog signals

  • Compact Design: Lightweight and space-efficient for cabinet installation

Application Scenarios

  • Process control in chemical and petrochemical industries

  • Power generation monitoring and turbine control

  • Water treatment and distribution automation

  • Industrial machinery requiring precise analog actuation

FAQ

Q: How many channels does the AAI543-H00 provide?  A: It supports 16 isolated analog output channels.

Q: Does this module support redundancy?  A: Yes, it includes standard switch-over response in dual-redundant setups.

Q: What communication protocol is available?  A: It supports HART protocol, enabling digital communication over analog signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more