The Schneider Electric TSXDSY32T2K drives high-density, low-power digital actuators within the Modicon Premium Automation platform. This 32-channel standard-format discrete output module utilizes solid-state protected circuitry to control 24V DC field components like miniature relay coils, solenoid valves, pneumatic pilot blocks, and electronic display indicators. By employing positive logic (source configuration) according to EN/IEC 61131-2 standards and integrating advanced electronic circuit protection, this module serves as a rapid, precise control interface for automated packaging machinery, conveyor sorting grids, and continuous process manufacturing lines.
Technical Specifications
| Parameter | Technical Specification Value |
| Manufacturer | Schneider Electric |
| Model / Part Number | TSXDSY32T2K |
| Range of Product | Modicon Premium Automation platform |
| Product or Component Type | Discrete output module |
| Condition | 100% Brand New Original |
| Discrete Output Number | 32 outputs |
| Discrete Output Type | Solid-state protected switching |
| Discrete Output Voltage Type | 24 V DC positive logic (source configuration) |
| Output Voltage Limits | 19 to 30 V DC (conforming to EN/IEC 61131-2) |
| Current Handling per Channel | 0.1 A nominal |
| Maximum Current per Module | 3.2 A total load capacity |
| Maximum Off-State Leakage Current | 0.1 mA at 30 V DC |
| Maximum Tungsten Load Rating | 1.2 W |
| Residual Voltage [Ures] | 1.5 V maximum across active output |
| Response Time | 1.2 ms state-to-state propagation delay |
| Paralleling of Outputs | Allowed: maximum of 3 outputs together |
| Output Overvoltage Protection | Integrated Transil protection diodes |
| Reverse Polarity Protection | Integrated reverse-mounted flyback diode network |
| Output Overload Protection | Automatic electronic trip circuitry |
| Short-Circuit Protection | Automatic electronic trip circuitry |
| Minimum Load Impedance | 220 Ohms at State 1 |
| Isolation Resistance Barrier | Greater than 10 MOhm at 500 V DC |
| Internal Power Dissipation | Calculated as: (1.6 W + 0.1 W x Number of active outputs) |
| Product Compatibility Matrix | Dial and Power systems |
| Electrical Connection Interface | 2 x High-density HE-10 male connectors |
| Internal Bus Current Demand | 140 mA at 5 V DC |
| Module Physical Format | Standard single-width slot profile |
| Product Net Weight | 0.7 lb (0.3 kg) |
Engineering Advantages
-
Self-Healing Overload and Short-Circuit Automatic Trip: Traditional fused output cards force plant maintenance teams to hunt through physical enclosures and replace individual wire-fuse elements whenever a field solenoid short-circuits. The TSXDSY32T2K solves this maintenance bottleneck by integrating a dedicated automatic electronic trip mechanism on every channel. If a short-circuit or an overcurrent event occurs on a field line, the active solid-state switch shuts down its own power path instantly within milliseconds, shielding the internal backplane logic and resetting automatically once technicians clear the field fault.
-
Dual HE-10 High-Density Pre-Formed Connector Interface: Stripping, pinning, and tightening 32 separate positive source wires manually onto standard screw-clamp blocks consumes vast amounts of installation time and increases panel footprint requirements. This module features two integrated HE-10 high-density connectors right on the front faceplate. This mechanical layout allows panel builders to plug pre-assembled ribbon cables or system interface harnesses directly into the card, condensing field multi-conductor lines into tight terminal arrangements while slashing system assembly duration.
-
Flexible Multi-Channel Paralleling for Dynamic Loads: Standard high-density PLC cards restrict output currents to minor milliamps, preventing the system from driving mid-sized field relays without using auxiliary interposing hardware. The TSXDSY32T2K provides unique wiring flexibility by supporting the structural paralleling of up to three individual channels. Combining three 0.1 A outputs allows engineers to safely switch a single load requiring up to 0.3 A of steady-state current, eliminating extra interface relays and saving panel cost.
-
Hardened Transil Diode Voltage Spike Suppression: High-inductive back-EMF spikes generated when collapsing the magnetic fields of miniature solenoid coils or mechanical relay lines can puncture standard output transistors, leading to frozen "always-on" failures. The TSXDSY32T2K incorporates robust Transil overvoltage suppression diodes across its solid-state circuits, alongside a reverse-mounted diode framework. This dual-layer suppression network clamps high-voltage inductive surges safely below hazardous levels, ensuring reliable switching performance inside electrically noisy control cabinets.
FAQs
-
Is this TSXDSY32T2K output module a brand new original item?
Yes. We supply this product strictly as a 100% brand new, original factory-sealed module. It ships directly to your facility inside its original Schneider Electric corporate box, complete with pristine anti-static protective bags, undamaged guide rails, and authentic manufacturer serialization markings.
-
Can I use this module to switch negative logic (sink) field devices?
No. The TSXDSY32T2K operates exclusively using positive logic (source configuration) according to EN/IEC 61131-2 specifications. When activated, an output channel supplies 24V DC from the external field supply straight to the connected load. Your field actuators must connect to the negative ground rail to complete the operating loop.
-
What type of cables should I buy to connect to the front faceplate?
This module requires two standard high-density HE-10 connector assemblies. You can utilize pre-formed ribbon cables or shielded multi-conductor pre-terminated bundles that feature matching female HE-10 connection ends to map the 32 discrete output points directly to your distribution terminal strips.
-
Does this module require external auxiliary power to operate the outputs?
Yes. While the module draws 140 mA of 5V DC power from the internal Modicon Premium backplane bus to run its logic and communication circuits, you must supply an external 24V DC power source (ranging between 19 and 30V DC) via your connector wire harness to drive the active field loads and power the internal solid-state protection switches.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.