Skip to content

What are you looking for?


You may also like

PS35*A Yokogawa Power Supply ModulePS35*A Yokogawa Power Supply ModulePS35*A Yokogawa Power Supply Module
PS35*A Yokogawa Power Supply Module
PS35*A Yokogawa Power Supply Module
PS35*A Yokogawa Power Supply Module

PS35*A Yokogawa Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : PS35*A

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for AC-to-DC power conversion and system rail bus distribution in Yokogawa control systems, the Yokogawa PS35*A (PS35 Power Supply Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model PS35*A
Brand Yokogawa
Origin Japan
Module Type Power Supply Module
Input Voltage AC Power Line Input
Output Voltage Regulated DC Bus Output
Mounting DIN Rail or Panel Mount
Operating Temp 0 to 50 deg C
Power Consumption Self-consumption internal power losses during conversion

Channel Isolation & Loop Power Infrastructure

The PS35*A power supply module incorporates internal galvanic isolation barriers between primary AC line connections, DC system buses, and protective ground earth. Galvanic decoupling prevents line transients and electrical noise from contaminating internal logic circuits and field loops, preserving signal resolution across attached 4-20 mA HART loop protocol transmitters and analog I/O modules.

Frequently Asked Questions

Q: How does electrical isolation inside the PS35*A protect downstream controller hardware?

A: Isolation transformer stages decouple the primary AC input line from the internal DC output rails, blocking common-mode noise and high-voltage surges from damaging controller backplanes.

Q: What mounting configurations support the physical installation of the PS35*A module?

A: The module supports direct DIN rail mounting or panel faceplate attachment depending on the base cabinet layout and carrier frame specification.

Field Installation Guidelines

Mount the PS35*A module securely onto the designated DIN rail track or cabinet panel baseplate. Verify that protective earth ground wiring is solidly bolted to the chassis ground terminal prior to applying primary AC power. Route incoming AC power connections in separate conduit runs away from low-voltage DC signals and 4-20 mA instrumentation lines to mitigate electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more