Skip to content

What are you looking for?


You may also like

PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port GatewayPLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port GatewayPLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway

PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway


Only 10 left - Selling fast

PRODUCT SKU : PLX31-EIP-MBS4

PRODUCT TYPE : Serial Communication Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The PLX31-EIP-MBS4 by ProSoft is a four-port serial communication gateway enabling seamless connection between EtherNet/IP networks and Modbus serial devices. It supports multiple Class 1 and Class 3 connections, providing high-speed, reliable data exchange in industrial automation systems.

Technical Specifications:

  • Manufacturer: ProSoft

  • Model / Part Number: PLX31-EIP-MBS4

  • Device Type: Serial Communication Gateway

  • EtherNet/IP Connections:

    • Class 3 Server: 5 connections

    • Class 1 I/O: 8 connections

    • I/O Connection Sizes: 248/248

    • Maximum RPI per connection: 5 ms

  • Serial Ports: 4 independent ports

  • Power Supply: 24 VDC nominal (10–36 VDC allowed)

  • Current Load: 24 VDC nominal @ 300 mA; max 10–36 VDC @ 610 mA

  • Operating Temperature: -25°C to 70°C (-13°F to 158°F)

  • Storage Temperature: -40°C to 80°C (-40°F to 176°F)

  • LED Indicators: Power, Error, Module Status, Network Status, Configuration

  • Dimensions (H x W x D): 13.67 x 5.05 x 11.13 cm

  • Weight: 2 kg

Features:

  • Provides reliable four-port serial connectivity

  • Supports high-speed EtherNet/IP to Modbus communication

  • Wide operating and storage temperature ranges

  • Industrial-grade LED indicators for network and module status

  • Compact design suitable for control panels and cabinets

Applications:

  • Integrating Modbus serial devices into EtherNet/IP systems

  • Data collection and monitoring in industrial automation

  • Real-time control in manufacturing or process applications

FAQ:
Q: How many serial devices can be connected?
A: Up to four serial devices per gateway, with isolated communication ports.

Q: What is the maximum EtherNet/IP RPI?
A: The maximum requested packet interval per connection is 5 ms.

Q: Is it compatible with Modbus RTU and ASCII?
A: Yes, the gateway supports both Modbus RTU and ASCII protocols.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Dynamic Data Exchange (DDE) remains a vital legacy protocol for industrial communication. Originally for general computing, it now bridges the gap between factory floor data and enterprise reporting. This enduring method provides a foundational link for integrating real-time software layers in modern industrial automation.

Read more
Master FIFO and LIFO Sequences for Advanced PLC Logic

Master FIFO and LIFO Sequences for Advanced PLC Logic

In industrial automation, managing data flow is as critical as hardware control. This guide explores how FIFO and LIFO sequential logic can optimize your control systems. Master these essential tools to build more efficient sorting, inventory tracking, and data management workflows for any modern factory.

Read more
Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

In industrial automation, distinguishing between power and signal cabling is vital. While power cables deliver energy to machinery, signal cables transmit critical data to control systems. This guide explores their technical differences and explains why proper isolation is the key to a reliable, interference-free factory automation network.

Read more