Skip to content

What are you looking for?


You may also like

PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port GatewayPLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port GatewayPLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway

PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway


Only 10 left - Selling fast

PRODUCT SKU : PLX31-EIP-MBS4

PRODUCT TYPE : Serial Communication Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The PLX31-EIP-MBS4 by ProSoft is a four-port serial communication gateway enabling seamless connection between EtherNet/IP networks and Modbus serial devices. It supports multiple Class 1 and Class 3 connections, providing high-speed, reliable data exchange in industrial automation systems.

Technical Specifications:

  • Manufacturer: ProSoft

  • Model / Part Number: PLX31-EIP-MBS4

  • Device Type: Serial Communication Gateway

  • EtherNet/IP Connections:

    • Class 3 Server: 5 connections

    • Class 1 I/O: 8 connections

    • I/O Connection Sizes: 248/248

    • Maximum RPI per connection: 5 ms

  • Serial Ports: 4 independent ports

  • Power Supply: 24 VDC nominal (10–36 VDC allowed)

  • Current Load: 24 VDC nominal @ 300 mA; max 10–36 VDC @ 610 mA

  • Operating Temperature: -25°C to 70°C (-13°F to 158°F)

  • Storage Temperature: -40°C to 80°C (-40°F to 176°F)

  • LED Indicators: Power, Error, Module Status, Network Status, Configuration

  • Dimensions (H x W x D): 13.67 x 5.05 x 11.13 cm

  • Weight: 2 kg

Features:

  • Provides reliable four-port serial connectivity

  • Supports high-speed EtherNet/IP to Modbus communication

  • Wide operating and storage temperature ranges

  • Industrial-grade LED indicators for network and module status

  • Compact design suitable for control panels and cabinets

Applications:

  • Integrating Modbus serial devices into EtherNet/IP systems

  • Data collection and monitoring in industrial automation

  • Real-time control in manufacturing or process applications

FAQ:
Q: How many serial devices can be connected?
A: Up to four serial devices per gateway, with isolated communication ports.

Q: What is the maximum EtherNet/IP RPI?
A: The maximum requested packet interval per connection is 5 ms.

Q: Is it compatible with Modbus RTU and ASCII?
A: Yes, the gateway supports both Modbus RTU and ASCII protocols.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more