Skip to content

What are you looking for?


You may also like

PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port GatewayPLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port GatewayPLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway
PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway

PLX31-EIP-MBS4 | ProSoft | EtherNet/IP to Modbus Serial 4-Port Gateway


Only 10 left - Selling fast

PRODUCT SKU : PLX31-EIP-MBS4

PRODUCT TYPE : Serial Communication Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The PLX31-EIP-MBS4 by ProSoft is a four-port serial communication gateway enabling seamless connection between EtherNet/IP networks and Modbus serial devices. It supports multiple Class 1 and Class 3 connections, providing high-speed, reliable data exchange in industrial automation systems.

Technical Specifications:

  • Manufacturer: ProSoft

  • Model / Part Number: PLX31-EIP-MBS4

  • Device Type: Serial Communication Gateway

  • EtherNet/IP Connections:

    • Class 3 Server: 5 connections

    • Class 1 I/O: 8 connections

    • I/O Connection Sizes: 248/248

    • Maximum RPI per connection: 5 ms

  • Serial Ports: 4 independent ports

  • Power Supply: 24 VDC nominal (10–36 VDC allowed)

  • Current Load: 24 VDC nominal @ 300 mA; max 10–36 VDC @ 610 mA

  • Operating Temperature: -25°C to 70°C (-13°F to 158°F)

  • Storage Temperature: -40°C to 80°C (-40°F to 176°F)

  • LED Indicators: Power, Error, Module Status, Network Status, Configuration

  • Dimensions (H x W x D): 13.67 x 5.05 x 11.13 cm

  • Weight: 2 kg

Features:

  • Provides reliable four-port serial connectivity

  • Supports high-speed EtherNet/IP to Modbus communication

  • Wide operating and storage temperature ranges

  • Industrial-grade LED indicators for network and module status

  • Compact design suitable for control panels and cabinets

Applications:

  • Integrating Modbus serial devices into EtherNet/IP systems

  • Data collection and monitoring in industrial automation

  • Real-time control in manufacturing or process applications

FAQ:
Q: How many serial devices can be connected?
A: Up to four serial devices per gateway, with isolated communication ports.

Q: What is the maximum EtherNet/IP RPI?
A: The maximum requested packet interval per connection is 5 ms.

Q: Is it compatible with Modbus RTU and ASCII?
A: Yes, the gateway supports both Modbus RTU and ASCII protocols.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more