Product Description

The MVI94-MCM-MHI module from ProSoft Technology is a Modbus Master/Slave communication interface designed for Allen Bradley FLEX I/O systems. It provides reliable connectivity for Modbus devices, supporting multiple serial protocols with robust isolation and diagnostic features.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: MVI94-MCM-MHI

  • Part Number: MVI94-MCM-MHI

  • Product Type: Modbus Master/Slave Module

  • Form Factor: Single-slot, 1794 backplane compatible

  • Backplane Current Load: 20 mA @ 5 VDC

  • External Power Supply: 12–24 VDC, 340–170 mA

  • Operating Temperature: 0–55°C (32–131°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Shock Resistance: 30 g operational, 50 g non-operational

  • Vibration Resistance: 5 g, 10–150 Hz

  • Relative Humidity: 5–95% non-condensing

  • LED Indicators: Module status, backplane transfer, application status, serial activity, error

  • Configuration Port (PRT1): Mini-DIN RS-232 with hardware handshaking

  • Application Port (PRT2): Mini-DIN RS-232/422/485, jumper selectable, 500 V optical isolation from backplane

  • Dimensions (with base): 3 × 3.7 × 2.7 in (94 × 94 × 69 mm)

Core Features

  • Supports Modbus Master and Slave communication modes

  • Optical isolation for enhanced reliability in industrial environments

  • Multiple serial interface options (RS-232/422/485)

  • Compact FLEX I/O form factor for flexible installation

  • LED indicators for real-time diagnostics and status monitoring

Application Scenarios

  • Integration of Modbus-based sensors, drives, and controllers into FLEX I/O systems

  • Distributed control systems requiring Modbus Master/Slave communication

  • Industrial automation setups needing reliable serial connectivity

FAQ

  • Q: Can the MVI94-MCM-MHI operate as both Master and Slave?  A: Yes, it supports both communication roles.

  • Q: What isolation level is provided?  A: The application port offers 500 V optical isolation from the backplane.

  • Q: What serial interfaces are supported?  A: RS-232, RS-422, and RS-485 are supported via jumper selection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more