Skip to content

What are you looking for?


You may also like

Foxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface ModuleFoxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface ModuleFoxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface Module
Foxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface Module
Foxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface Module
Foxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface Module

Foxboro FBM218 P0922VW I/A Series HART Communication Redundant Output Interface Module


Only 10 left - Selling fast

PRODUCT SKU : FBM218 P0922VW

PRODUCT TYPE : HART Communication Module

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Foxboro FBM218 (P0922VW) provides high-integrity HART digital communication and analog output capabilities for the Foxboro I/A Series Distributed Control System (DCS). This module features eight isolated output channels designed to interface with smart field devices such as valve positioners and actuators. It bridges the gap between the DCS control database and the field, enabling both primary variable control and advanced asset management through HART data passthrough. We supply this unit as 100% Brand New and Original, ensuring your critical control loops operate with factory-certified precision and zero previous field runtime.

Technical Specifications

Feature Specification Details
Manufacturer Foxboro (by Schneider Electric)
Model Number FBM218
Part Number P0922VW
Interface Type 8 Isolated Output Channels
HART Compatibility HART Specifications Version 5, 6, or 7
Isolation Strength 600 V AC (1 minute) channel-to-earth
Isolation Method Galvanic (Optical and Transformer Isolation)
Fieldbus Speed 2 Mbps HDLC Redundant Fieldbus
Operating Temperature -20 to +70°C (-4 to +158°F)
Dimensions (LxWxH) 10.4 cm x 4.5 cm x 11.4 cm
Net Weight 0.284 kg

Engineering Advantages

The FBM218 P0922VW resolves critical signal integrity and availability challenges in complex processing plants:

  • Triple-Layer Galvanic Isolation: The module incorporates both optical and transformer isolation between individual channels, ground, and logic circuitry. This architecture repels electromagnetic interference (EMI) and prevents ground loops from corrupting the 4-20mA signal or the superimposed HART digital data.

  • Uninterrupted Redundant Communication: The hardware maintains constant contact with the associated FCM or FCP via a high-speed 2 Mbps HDLC redundant Fieldbus. This dual-path architecture ensures the DCS retains control over field actuators even if a primary communication path fails.

  • Universal HART Tool Integration: Supporting HART versions 5, 6, and 7, the FBM218 allows engineers to execute remote calibration, diagnostics, and configuration of smart field instruments directly from the DCS workstation. This eliminates the need for technicians to use handheld communicators in hazardous field areas.

  • Robust Transient Protection: The internal circuitry withstands a potential of 600 V AC applied for one minute between channels and earth. This protects the module logic from catastrophic damage during lightning strikes or major electrical faults in the plant's power distribution system.

  • Streamlined Maintenance Footprint: The compact 4.5 cm width optimizes rail space in high-density I/O cabinets. The "hot-swap" capability allows for the immediate replacement of modules without disrupting the power or communication of neighboring units on the same baseplate.

FAQs

  • Does the FBM218 P0922VW support both input and output HART signals?

    No, the FBM218 specializes in output interface tasks. It drives field devices like valve positioners. For HART input requirements (such as transmitters), you should utilize the corresponding FBM217 or similar input-specific modules.

  • Can I use this module with older HART Version 5 instruments?

    Yes. The FBM218 maintains full backward compatibility. It supports HART instruments compliant with Version 5, 6, or 7 of the HART specifications.

  • How do I ensure the module condition is factory-fresh?

    We guarantee every unit is 100% Brand New. Each module arrives in original Foxboro factory-sealed packaging, ensuring all internal capacitors and semiconductors meet their full theoretical Mean Time Between Failures (MTBF) without degradation from previous use.

  • Is the Termination Assembly (TA) included in the module temperature rating?

    The module itself operates up to +70°C (+158°F). However, if you use a PVC-based Termination Assembly, you must limit the ambient temperature at the TA to +50°C (+122°F) to prevent material degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Power Supply Sizing for Industrial Automation Systems

Optimizing Power Supply Sizing for Industrial Automation Systems

The power supply is the silent heartbeat of any industrial automation system. While engineers often prioritize processors and communication protocols, a stable power architecture remains the most critical factor for long-term reliability. In my 15 years of experience, I have found that neglecting power supply sizing often leads to ghost errors, intermittent field device failures, and costly production downtime.

Read more
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more