Foxboro BS805MD Electrode KitFoxboro BS805MD Electrode KitFoxboro BS805MD Electrode Kit
Foxboro BS805MD Electrode Kit
Foxboro BS805MD Electrode Kit
Foxboro BS805MD Electrode Kit

Foxboro BS805MD Electrode Kit


Only 10 left - Selling fast

PRODUCT SKU : BS805MD

PRODUCT TYPE : Sensor Accessories

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for electrochemical measurement loops in Foxboro 871PH sensor assemblies, the Foxboro BS805MD (BS805MD Electrode Kit) provides direct physical fluid-to-electrode contact via flat glass pH sensing elements, titanium wetted parts, and a rugged Ryton body structure.

Hardware Specifications

Parameter Specification
Model BS805MD
Brand Foxboro
Weight 0.20 lbs
Operating Temp Industrial Standard Temperature Limits
Power Consumption Passive sensor component (0 W)
Electrode Type Flat glass pH element
Wetted Materials Titanium wetted parts
Body Material Ryton body
Compatibility Foxboro 871PH Sensor Assemblies

Foxboro Process Control and 4-20 mA Loop Integration

Operating within electrochemical analytical loops in Foxboro DCS architectures, the BS805MD electrode kit interfaces directly with preamplifier and transmitter electronics to convert hydrogen ion activity into a millivolt signal. While process control loops routinely transmit data via 4-20 mA HART protocol or FOUNDATION Fieldbus links, pH measurement relies on high-impedance electrical signal generation where cable capacitance and ground leakage must be strictly minimized. The titanium wetted parts and durable Ryton body construction ensure chemical resistance and channel isolation against aggressive process media, preserving analytical signal integrity within industrial process streams.

Frequently Asked Questions

Q: Can the BS805MD electrode kit be replaced while the 871PH sensor assembly remains inserted in a pressurized process line?

A: Hot-extracting pH electrodes from pressurized process lines without isolation valves or retractable process fittings can result in chemical exposure and process leakage; always depressurize and isolate the sample point prior to maintenance.

Q: What precautions are required when handling the flat glass pH element during installation?

A: Avoid touching or abrading the flat glass surface with hard objects; contamination or physical micro-fractures on the glass membrane will cause calibration drift and reading errors.

Q: How do titanium wetted parts contribute to measurement stability in corrosive streams?

A: Titanium wetted parts prevent galvanic corrosion and localized pitting when exposed to aggressive chemical process fluids, maintaining a stable reference ground path for the electrode cartridge.

Field Installation Guidelines

  • Rinse the electrode cartridge with deionized water and inspect the flat glass membrane and O-ring seals for physical defects before insertion into the 871PH housing.
  • Ensure proper alignment of the electrode indexing pins with the sensor body slots to prevent bending or shearing of internal electrical contact pins.
  • Torque threaded retaining caps securely according to manufacturer specifications to maintain fluid-tight sealing under maximum process pressure ratings.
  • Perform a standard two-point buffer calibration on the transmitter electronics after installation to account for baseline electrode potential shifts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more