Skip to content

What are you looking for?


You may also like

Bently Nevada 3500/25-02-01-05 Enhanced Keyphasor ModuleBently Nevada 3500/25-02-01-05 Enhanced Keyphasor ModuleBently Nevada 3500/25-02-01-05 Enhanced Keyphasor Module
Bently Nevada 3500/25-02-01-05 Enhanced Keyphasor Module
Bently Nevada 3500/25-02-01-05 Enhanced Keyphasor Module
Bently Nevada 3500/25-02-01-05 Enhanced Keyphasor Module

Bently Nevada 3500/25-02-01-05 Enhanced Keyphasor Module


Only 10 left - Selling fast

PRODUCT SKU : 3500/25-02-01-05

PRODUCT TYPE : Keyphasor Modules

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 3500/25-02-01-05 Enhanced Keyphasor Module is a half-height, two-channel module designed for the Bently Nevada 3500 Series Machinery Protection System. It acquires input signals from proximity transducers or magnetic pickups to provide precise rotational speed, phase angle, and vector measurements for rotating machinery. This specific configuration features an I/O module with external terminations, internal barriers, and agency approvals for hazardous locations.

Signal Processing and Phase Reference

The module processes shaft-mounted keyway or notch target waveforms to generate digital timing pulses utilized across the 3500 framework. These Keyphasor pulses enable synchronous sampling, precise vibration vector calculations, and advanced phase analysis for machinery protection monitors. Each independent channel conditions incoming signals to reject electrical noise and maintain stable speed tracking through transient and steady-state operations.

Hardware Configuration and I/O Interface

Occupying two front slots within a standard 3500 rack, the assembly pairs the main processor board with a designated rear I/O module. The -02 designation indicates an I/O module option configured with external terminations, routing field wiring through separate termination blocks. The -01 and -05 suffixes denote internal barrier provisions and multi-agency certifications for hazardous areas. Front-panel LED indicators provide real-time status for channel operation, transducer power supply health, and module readiness.

Parameter Specification
Model 3500/25-02-01-05
Brand Bently Nevada
Product Type Enhanced Keyphasor Module
Number of Channels 2 channels
Transducer Inputs Proximity transducers or magnetic pickups
I/O Module Type External terminations [-02]
Barriers and Approvals Internal barriers with agency approvals [-01-05]
Slot Occupancy 2 rack slots
Operating Temperature -30 degC to +65 degC
Storage Temperature -40 degC to +85 degC
Weight 0.91 kg

Frequently Asked Questions

Q: What is the primary role of the 3500/25-02-01-05 module?

A: It provides reliable keyphasor reference signals, rotational speed tracking, and phase angle measurements for vibration monitoring modules in a 3500 rack.

Q: What sensor types are compatible with this enhanced keyphasor module?

A: It accepts input signals from standard eddy-current proximity transducers as well as passive magnetic speed pickups.

Q: What do the configuration suffixes -02-01-05 represent?

A: They specify an I/O module with external terminations, internal barrier circuitry, and certified hazardous location agency approvals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more