ABB REF 601 Feeder Protection and Control RelayABB REF 601 Feeder Protection and Control RelayABB REF 601 Feeder Protection and Control Relay
ABB REF 601 Feeder Protection and Control Relay
ABB REF 601 Feeder Protection and Control Relay
ABB REF 601 Feeder Protection and Control Relay

ABB REF 601 Feeder Protection and Control Relay


Only 10 left - Selling fast

PRODUCT SKU : REF 601

PRODUCT TYPE : Feeder Protection Relay

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The ABB REF 601 feeder protection and control relay is a compact, pre-configured device from the Relion 605 series. It is specifically designed for medium-voltage applications in utility substations and industrial power systems. Supporting both Rogowski coil sensor technology and conventional current transformers (CTs), it provides versatile protection and control functionality.

Technical Specifications

  • Product Version: 2.0

  • Nominal Input Voltage: 24–240 V AC/DC

  • Sensor Inputs: 3 Rogowski coil inputs

  • Earth Fault Input: 1 core balance CT input (1 A)

  • Binary Inputs: 4 (remote trip, reset, close, open)

  • Binary Outputs: 2 trip, 2 signaling, 1 breaker close, 1 unit ready/IRF

  • Mounting Depth: 102 mm

  • Weight: 1.2 kg

  • Communication Protocols: Modbus RTU, IEC 60870-5-103

  • Interface: RS485 (2-wire)

  • Protection Class: IP42 (front), IP20 (sides)

  • EMC Compliance: IEC 60255-26, EN 50263

  • Safety Standards: EN 60255-27, EN 60255-1

  • RoHS Compliance: Yes

Functional Highlights

  • Overcurrent Protection: Three-stage (low, high, very high)

  • Earth-Fault Protection: Two-stage (low, high)

  • Transformer Inrush Detection: Second harmonic blocking method

  • Negative Phase Sequence Protection: Detects imbalance and discontinuity

  • Circuit Breaker Failure Protection: Ensures system reliability

  • Thermal Overload Protection: For feeders, cables, and transformers

  • Auto-Reclose Functionality: Multi-shot capability

  • Trip Circuit Supervision: Monitors breaker trip circuits

  • Configurable Logic Gates: Flexible system integration

  • Event Logging & Fault Recording: Non-volatile memory storage

Application Scenarios

  • Medium-voltage feeder protection in utility substations

  • Industrial power distribution systems requiring compact relay solutions

  • Systems using Rogowski coil sensors or conventional CTs

FAQ

Q: Does the REF601 support both Rogowski coils and CTs?  A: Yes, it is compatible with Rogowski coil sensors and conventional current transformers.

Q: What communication protocols are available?  A: The relay supports Modbus RTU and IEC 60870-5-103 via RS485 interface.

Q: How is transformer inrush detected?  A: The relay uses second harmonic blocking to distinguish inrush currents from faults.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more