Description

The ABB INICT03 is a high-performance communication interface for Bailey Infi 90 and Network 90 DCS, connecting Cnet to external systems or consoles. It converts internal protocols into standard serial or Ethernet data, enabling real-time monitoring, configuration, and data logging. The INICT03 ensures secure, deterministic communication for plant-wide control strategies.

Specifications

  • Brand: ABB Bailey

  • Model Number: INICT03

  • Product Type: Cnet Transfer Module

  • Series: Infi 90 / Network 90

  • Data Interface: Cnet to RS-232-C / RS-485

  • Baud Rates: Configurable for various transmission speeds

  • Net Weight: 0.62 kg (1.37 lbs)

  • Power Supply: 5 VDC via MMU Backplane

Features

  • Bi-Directional Communication: Facilitates seamless data flow between the Infi 90 network and third-party supervisory software or HMIs.

  • Protocol Translation: Efficiently converts proprietary Cnet data packets into readable formats for external processing and analysis.

  • System Isolation: Protects the integrity of the control network by providing a secure hardware buffer for computer-level requests.

  • Diagnostic Monitoring: Integrated front-panel LEDs offer immediate status updates on network activity and module health.

  • Redundant Support: Engineered for compatibility in high-availability configurations to prevent data loss during communication failovers.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Upstream oil and gas operations rely on specialized field control platforms to manage wellhead extraction safety and hydraulic actuation. A Wellhead Control Panel (WHCP) serves as a dedicated hydraulic and pneumatic power unit designed to operate critical Christmas Tree isolation valves. By interfacing field safety components directly with Programmable Logic Controller (PLC) architecture, a WHCP protects upstream extraction assets against overpressure, catastrophic leaks, and thermal emergencies.

Read more
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more