Skip to content

What are you looking for?


You may also like

ABB IMNPM01 Bailey Infi 90 Network Processor Communication ModuleABB IMNPM01 Bailey Infi 90 Network Processor Communication ModuleABB IMNPM01 Bailey Infi 90 Network Processor Communication Module
ABB IMNPM01 Bailey Infi 90 Network Processor Communication Module
ABB IMNPM01 Bailey Infi 90 Network Processor Communication Module
ABB IMNPM01 Bailey Infi 90 Network Processor Communication Module

ABB IMNPM01 Bailey Infi 90 Network Processor Communication Module


Only 10 left - Selling fast

PRODUCT SKU : IMRI002

PRODUCT TYPE : Remote I/O Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB IMRIO02 is a communication interface for Bailey Infi 90 and Network 90 DCS, connecting local Master Controllers to remote I/O modules. It supports high-speed data transmission over long distances, reducing field wiring costs and enabling decentralized signal acquisition. By maintaining a reliable link to the system backplane, the IMRIO02 ensures low-latency, high-integrity data integration from remote locations.

Specifications

  • Brand: ABB Bailey

  • Model Number: IMRIO02

  • Product Type: Remote I/O Interface Module

  • Series: Infi 90 / Network 90

  • Communication Link: Remote I/O Bus

  • Isolation: Built-in galvanic isolation for noise immunity

  • Net Weight: 0.61 kg (1.34 lbs)

  • Mounting: Standard MMU Rack mount

Features

  • Extended Network Range: Enables the placement of I/O hardware closer to the process equipment while maintaining a reliable link to the central processor.

  • Deterministic Data Exchange: Optimized for synchronous communication, ensuring time-critical process variables are updated without jitter.

  • Integrated Diagnostics: Features onboard self-testing and front-panel status LEDs to monitor the health of the remote communication link.

  • Robust Hardware Design: Specifically built for industrial environments with high electromagnetic interference (EMI) and varying thermal conditions.

  • Efficient Integration: Plugs directly into the Infi 90 Slave Bus to streamline the addition of remote sub-racks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more