Skip to content

What are you looking for?


You may also like

ABB GIS810 3BSE078740R1 Select I/O Series Generic I/O ModuleABB GIS810 3BSE078740R1 Select I/O Series Generic I/O ModuleABB GIS810 3BSE078740R1 Select I/O Series Generic I/O Module
ABB GIS810 3BSE078740R1 Select I/O Series Generic I/O Module
ABB GIS810 3BSE078740R1 Select I/O Series Generic I/O Module
ABB GIS810 3BSE078740R1 Select I/O Series Generic I/O Module

ABB GIS810 3BSE078740R1 Select I/O Series Generic I/O Module


Only 10 left - Selling fast

PRODUCT SKU : GIS810 3BSE078740R1

PRODUCT TYPE : Generic I/O Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density physical signal execution in Select I/O sub-rack systems, the ABB GIS810 3BSE078740R1 (GIS810 Generic I/O Module) provides direct physical/electrical execution for multi-parameter channel processing.

Hardware Specifications

Parameter Specification
Model GIS810 3BSE078740R1
Brand ABB
Origin Sweden / Switzerland
Weight 76 g (including base)
Dimensions 77.9 mm (Width) x 108 mm (Depth) x 15.8 mm (Height)
Operating Temp -40 to +70 deg C (Storage: -40 to +85 deg C)
Power Consumption 0.4 W maximum power dissipation
Product Type Generic I/O Modules
HART Protocol Supported
Sequence of Events (SOE) Supported
Hardware Redundancy Supported
Hot Swap capability Yes
High Integrity rating No
Altitude restrictions -1000 to 5000 m (restrictions apply)
Relative Humidity 5% to 95%, non-condensation
Pollution Degree Pollution Degree 2 according to IEC 60664-1
Hazardous Area Installation Certified for locations / hazardous zones

Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling

The interface card processes real-time device mapping values across the sub-rack assembly, maintaining strict schedule timing intervals without lowering backplane bus communication velocity. The architecture supports rapid I/O density scaling options on the Select I/O block while updating digital variables and embedded HART data frames. The internal mapping engine synchronizes parallel channel logs with deterministic communication protocols, safeguarding data blocks and verifying firmware flash compatibility profiles across active field processing loops.

Frequently Asked Questions

Q: What diagnostics loops run during active execution to trace errors within the GIS810 module?

A: The module executes concurrent internal hardware supervision, continuous communication bus supervision, and independent internal power supervision tracks. Any deviation trips the module state registers and maps the technical fault data to the upper network block.

Q: Are there operational restrictions or delays during an online hot-swap procedure?

A: The GIS810 supports online hot-swap insertion and extraction under active backplane power conditions. When deployed in a redundant pair configuration, hardware state replication ensures zero signal loss or latency disruption to the active network process loop during physical exchange.

Field Installation Guidelines

  • Chassis Engagement: Insert the module into the designated Select I/O base track guide until the backplane multi-pin interface aligns. Tighten structural latch mechanisms to ensure mechanical lock and electrical continuity.
  • Shield Ground Separation: Terminate field device loop shield extensions to the dedicated cabinet grounding rail. Maintain isolated structural paths to prevent ground currents from affecting the 4-20 mA HART signal lines.
  • Hazardous Area Containment: For installations inside certified hazardous areas, verify that the outer cabinet structure matches or exceeds local explosion-protection rules before applying active 24 VDC loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Remote Terminal Units: The Core of SCADA and Telemetry Systems

Understanding Remote Terminal Units: The Core of SCADA and Telemetry Systems

In industrial automation, engineers often debate the choice between a Programmable Logic Controller (PLC) and...
Read more
Ultimate Guide to Schneider Electric PLCs: Selecting Control Systems for Small to Medium Automation

Ultimate Guide to Schneider Electric PLCs: Selecting Control Systems for Small to Medium Automation

Schneider Electric remains a dominant force in global industrial automation, delivering robust control systems across diverse sectors. For control engineers, selecting the right programmable logic controller (PLC) requires balancing budget, communication ports, and processing power. This technical breakdown explores Schneider’s small and medium portfolio, offering field-tested insights to help you optimize your next factory automation project.

Read more
Essential Maintenance Guide for PLC, DCS, and ESD Marshalling Cabinets

Essential Maintenance Guide for PLC, DCS, and ESD Marshalling Cabinets

Marshalling cabinets serve as the vital interface between field instrumentation and your core control systems. In large-scale industrial automation, these panels house the intricate wiring for PLC, DCS, and Emergency Shutdown (ESD) systems. Regular, systematic health checks are non-negotiable to ensure operational reliability and prevent costly unplanned downtime.

Read more