Skip to content

What are you looking for?


You may also like

ABB CI857 3BSE018144R1 System 800xA INSUM Communication InterfaceABB CI857 3BSE018144R1 System 800xA INSUM Communication InterfaceABB CI857 3BSE018144R1 System 800xA INSUM Communication Interface
ABB CI857 3BSE018144R1 System 800xA INSUM Communication Interface
ABB CI857 3BSE018144R1 System 800xA INSUM Communication Interface
ABB CI857 3BSE018144R1 System 800xA INSUM Communication Interface

ABB CI857 3BSE018144R1 System 800xA INSUM Communication Interface


Only 10 left - Selling fast

PRODUCT SKU : CI857 3BSE018144R1

PRODUCT TYPE : Communication Interface Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB CI857 is a high-performance communication interface designed to integrate the INSUM (Integrated System for User-optimized Motor control) system with ABB System 800xA. Operating as a gateway for AC 800M controllers, this module enables the supervision and control of intelligent switchgear and motor control centers. By utilizing the 3BSE013233R1 hardware, it provides a dedicated link to motor protection relays and power management devices, ensuring that critical electrical data is available for real-time process decision-making and asset optimization.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Switzerland

  • Model Number: CI857

  • Order Code: 3BSE018144R1

  • Product Type: INSUM Communication Interface

  • Dimensions: 186 mm x 46.5 mm x 135 mm

  • Weight: 0.6 kg

  • Protocol Support: LonWorks based INSUM protocol

  • Data Rate: 78.1 kbit/s (LonWorks TP/FT-10)

  • Power Supply: 24V DC (Internal via controller bus)

Features

  • Intelligent Integration: Direct connection between AC 800M controllers and INSUM motor control devices for comprehensive motor management.

  • Bi-directional Data Flow: Supports both the transmission of control commands and the retrieval of diagnostic and measurement data.

  • System 800xA Optimized: Engineered for native configuration within the ABB 800xA Control Builder environment.

  • Efficient Engineering: Simplifies the wiring and commissioning of smart switchgear by replacing traditional hardwired I/O with digital communication.

  • Module Redundancy: Supports redundant module setups to ensure continuous communication with critical electrical infrastructure.

  • Real-time Monitoring: Facilitates advanced preventative maintenance by reporting motor current, voltage, and thermal load data.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more