Skip to content

What are you looking for?


You may also like

ABB CI 930F 3BDH001010R0002 Communication InterfaceABB CI 930F 3BDH001010R0002 Communication InterfaceABB CI 930F 3BDH001010R0002 Communication Interface
ABB CI 930F 3BDH001010R0002 Communication Interface
ABB CI 930F 3BDH001010R0002 Communication Interface
ABB CI 930F 3BDH001010R0002 Communication Interface

ABB CI 930F 3BDH001010R0002 Communication Interface


Only 10 left - Selling fast

PRODUCT SKU : CI 930F 3BDH001010R0002

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB CI 930F 3BDH001010R0002, also cataloged as the CI 930F Communication Interface, operates as a dedicated hardware component for PROFIBUS DP master fieldbus communication within ABB Freelance AC 900F automation platforms.

Hardware Specifications

Parameter Specification
Model CI 930F 3BDH001010R0002
Brand ABB
Origin Standard ABB Manufacturing
Weight 0.115 kg
Dimensions 28 mm x 85 mm x 152 mm
Operating Temp -20 to +60 deg C (Standard Industrial Range)
Power Consumption 1.8 W (80 mA typ. via 24 VDC CPU module terminal)
Communication Protocol PROFIBUS DP Master
Transmission Speed 9.6 kBit/s to 12 MBit/s
Physical Interface Two 9-pole D-Sub female connectors
Redundancy Support Line redundancy supported
Hot-Swap Capability Supported

Profinet / EtherNet/IP Deterministic Networks & Backplane Communication Velocity

The CI 930F interface facilitates deterministic data exchanges across PROFIBUS DP and higher-level automation networks, maintaining cyclical signal sync at transmission speeds reaching 12 MBit/s. Backplane bus communication velocity allows rapid data interchange between the local CPU module and field slaves. Integrated firmware flash compatibility guarantees seamless node configuration, line redundancy management, and online diagnostics across connected subrack backplanes without interrupting ongoing processor scan cycles.

Frequently Asked Questions

Q: Can the CI 930F communication module be hot-swapped during active system operation?

A: Yes, the CI 930F hardware supports hot-swapping, allowing module replacement while the remaining controller backplane components remain powered.

Q: How is the auxiliary operating power delivered to the CI 930F card?

A: Power is drawn directly through the internal backplane connection via the 24 VDC supply terminal on the host CPU module, drawing a typical load of 80 mA (1.8 W power dissipation).

Field Installation Guidelines

  • Ensure the base CPU or subrack assembly is grounded to the control panel earth rail using a low-impedance conductor prior to powered operation.
  • Secure standard 9-pole D-Sub bus connectors to the front ports using their integrated locking screws to maintain shield continuity.
  • Maintain proper line termination resistors on the physical end nodes of the PROFIBUS network segment to prevent signal reflections.
  • Adhere to strict cable routing separations, keeping PROFIBUS signal cables isolated from high-voltage AC power wiring and drive outputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more