The YOKOGAWA AAI141-H00/K4A00, also cataloged as the AAI141 Analog Input Module, operates as a dedicated hardware component for 16-channel 4-20 mA analog signal acquisition with HART digital communication within YOKOGAWA CENTUM control system networks. The assembly includes an ATK4A-00 KS cable interface adapter to enable multi-core cable termination.

Suffix Breakdown & Model Matrix

The catalog designation for the AAI141-H00/K4A00 defines specific hardware capabilities and interface options:

  • Base Model (AAI141): Analog Input Module (4 to 20 mA, 16-channel, Non-Isolated)
  • Communication Suffix (-H): With digital communication (HART protocol)
  • Option Code (0): Always 0
  • Option Code (0): Basic type
  • Adapter Option (/K4A00): Equipped with KS Cable Interface Adapter [Model: ATK4A-00]

Hardware Specifications

Parameter Specification
Model AAI141-H00/K4A00
Brand YOKOGAWA
Origin Japan
Operating Temp -20 to 60 deg C
Input Channels 16 channels, non-isolated
Input Signal Range 4 to 20 mA DC
Digital Communication HART protocol (superimposed on 4-20 mA current loop)
Cable Adapter ATK4A-00 KS Cable Interface Adapter
System Compatibility YOKOGAWA CENTUM VP / CENTUM CS 3000 FIO

4-20 mA HART Loop Protocol and Signal Acquisition

The AAI141-H00/K4A00 converts 16 non-isolated 4-20 mA current loop signals into digital data frames for DCS backplane processing. Superimposed HART protocol communication enables simultaneous pass-through of secondary process variables, transmitter diagnostic data, and configuration parameters without disturbing analog control loops. The attached ATK4A-00 KS cable interface adapter translates board-level connections into multi-conductor KS cable interfaces for streamlined connection to field terminal panels.

Frequently Asked Questions

Q: What function does the /K4A00 option serve on the AAI141-H00/K4A00 module?

A: The /K4A00 option equips the module with an integrated ATK4A-00 KS cable interface adapter, facilitating multi-core KS cable connections to external termination blocks.

Q: Are the 16 analog input channels on the AAI141-H00/K4A00 individually isolated?

A: No, the AAI141 module features a non-isolated architecture where all 16 input channels share a common circuit ground reference.

Q: Does the AAI141-H00/K4A00 module support HART communications across all 16 channels?

A: Yes, the -H suffix indicates built-in HART digital communication support across all 16 analog input channels simultaneously.

Field Installation Guidelines

Ensure backplane power is isolated or verify online hot-swap safety procedures before inserting the module into an FIO node slot. Wear a grounded ESD wrist strap when handling the card. Align the module with rack guide rails and press firmly to seat the backplane connector, securing top and bottom retaining screws to establish frame ground continuity. Connect the multi-core KS cable to the ATK4A-00 adapter interface, locking physical latches to prevent signal disconnection. Connect field wiring shields to a single cabinet earth terminal bar to mitigate ground loop noise.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Engineering Guide: Power Supply Sizing for PLC and DCS Control Systems

Engineering Guide: Power Supply Sizing for PLC and DCS Control Systems

Stable 24 VDC power architectures form the foundation of reliable automation. This guide explores essential power supply unit (PSU) sizing methods, key design parameters, vendor configurators, and field isolation strategies to prevent CPU resets and ensure continuous process operation.
Read more
Interface Philosophy Between DCS and Motor Control Centers in Industrial Automation

Interface Philosophy Between DCS and Motor Control Centers in Industrial Automation

Modern industrial automation relies on seamless integration between Distributed Control Systems (DCS) and Motor Control Centers (MCC). This technical guide explores essential signal exchange methods, hardware isolation protocols, and VFD integration strategies to ensure high availability in process plants.
Read more
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more