Skip to content

What are you looking for?


You may also like

900PSM-0200 HC900 Power Status Module | Honeywell900PSM-0200 HC900 Power Status Module | Honeywell900PSM-0200 HC900 Power Status Module | Honeywell
900PSM-0200 HC900 Power Status Module | Honeywell
900PSM-0200 HC900 Power Status Module | Honeywell
900PSM-0200 HC900 Power Status Module | Honeywell

900PSM-0200 HC900 Power Status Module | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : 900PSM-0200

PRODUCT TYPE : Power Supplies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for power supply health monitoring and status indication in ControlEdge HC900 architectures, the Honeywell 900PSM-0200 (900PSM Power Status Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 900PSM-0200
Brand Honeywell
Origin USA
Weight 2.00 kg (shipping weight)
Dimensions Standard HC900 rack slot footprint
Operating Temp 0 deg C to 60 deg C
Power Consumption 22 mA max at 5 VDC
Operating Voltage 5 VDC logic bus
Module Type Power Status Module
Application ControlEdge HC900 Series Controller
Product Category Power Supplies / Power Status Module

Channel-to-Channel Isolation & DCS Power Architecture

The 900PSM-0200 module continuously evaluates status signals from redundant rack power supplies across internal 5 VDC logic buses. It interfaces directly with central processing units executing 4-20 mA HART loop protocol algorithms and I/O channels. Internal channel-to-channel isolation circuits prevent bus noise, potential ground loops, and voltage dips from propagating into parallel process control loops or disrupting communication buses within the rack assembly.

Frequently Asked Questions

Q: What is the maximum current draw of the 900PSM-0200 from the internal logic bus?

A: The module consumes a maximum current of 22 mA at 5 VDC from the backplane supply.

Q: Does the 900PSM-0200 require external field power to monitor power supply health?

A: No, operating logic power is drawn directly from the internal 5 VDC backplane bus rail.

Field Installation Guidelines

  1. Isolate the rack power supply sources before inserting or removing the status module to avoid transient bus disruptions.
  2. Ensure the board edge connectors align fully with the designated backplane slot before seating the module.
  3. Tighten the module retaining screws to secure chassis ground continuity and withstand vibration.
  4. Verify all power supply status wiring and ground connections adhere to single-point instrumentation grounding standards.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more