Skip to content

What are you looking for?


You may also like

51305557-100 | Honeywell | Control System Heavy-Duty Power Cable51305557-100 | Honeywell | Control System Heavy-Duty Power Cable51305557-100 | Honeywell | Control System Heavy-Duty Power Cable
51305557-100 | Honeywell | Control System Heavy-Duty Power Cable
51305557-100 | Honeywell | Control System Heavy-Duty Power Cable
51305557-100 | Honeywell | Control System Heavy-Duty Power Cable

51305557-100 | Honeywell | Control System Heavy-Duty Power Cable


Only 10 left - Selling fast

PRODUCT SKU : 51305557-100

PRODUCT TYPE : Power Cable

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51305557-100 functions as a heavy-duty, mains power cable assembly custom-engineered for Honeywell control systems, process servers, and industrial chassis. This cable establishes a secure, continuous AC power connection between structural power distribution units (PDUs) and sensitive system nodes. We supply this component in 100% brand new, original factory condition to meet strict facility safety compliance codes and safeguard continuous control room operations.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number 51305557-100
Input Voltage 220V AC
Current Rating 10A
Cable Jacket Type SJT (Service Junior Thermoplastic)
Conductor Gauge 16 AWG
Length 1.2 meters (4 feet)
Connector End A Standard IEC 60320 C13 (Socket)
Connector End B NEMA 5-15P (Plug)
Operating Temperature -20°C to +70°C (-4°F to +158°F)
Compliance Meets relevant industrial electrical safety standards

Engineering Advantages

  • Prevents Accidental Thermal Overloads: The heavy-duty 16 AWG copper conductors handle a continuous 10A current load at 220VAC without generating localized resistance heat. This layout prevents degradation of the inner wire core in unventilated enclosure spaces.

  • Resists Chemical and Mechanical Wear: The rugged SJT thermoplastic jacket protects the inner conductors against abrasions, physical pinching, and accidental chemical exposure typical of industrial plant environments.

  • Ensures Friction-Fit Connection Stability: Precise molding tolerances on the IEC 60320 C13 receptacle ensure a tight, vibration-resistant friction grip when plugged into the device power supply inlet, eliminating intermittent arcing and micro-outages.

  • Optimizes Dense Cable Management Tray Layouts: The 1.2-meter (4 feet) length minimizes excess slack inside standard 19-inch server racks and Marshalling cabinets. This layout keeps air pathways clear and prevents thermal buildup around critical system processors.

FAQs

  • Can I utilize this cable safely in extreme outdoor temperature conditions?

    The 51305557-100 cable carries an operating temperature rating of -20°C to +70°C. While it withstands significant internal cabinet heat and freezing control room failures, you must protect it within liquid-tight conduit if running it through raw outdoor elements.

  • Is this cable an authentic Honeywell product or a generic equivalent?

    We guarantee this product is a 100% brand new, original Honeywell cable assembly. It ships directly in original factory packaging to fulfill high-reliability DCS deployment requirements.

  • Does the NEMA 5-15P plug configuration allow 220VAC operation safely?

    Yes. The heavy-duty SJT insulation and inner core components fully support a 220VAC potential up to a 10A draw. Ensure that your plant source receptacle matches the NEMA 5-15P pinning configuration and delivers the appropriate voltage specified by your hardware manual.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more