Skip to content

What are you looking for?


You may also like

3500/15-04-00-00 | Bently Nevada Power Supply Module3500/15-04-00-00 | Bently Nevada Power Supply Module3500/15-04-00-00 | Bently Nevada Power Supply Module
3500/15-04-00-00 | Bently Nevada Power Supply Module
3500/15-04-00-00 | Bently Nevada Power Supply Module
3500/15-04-00-00 | Bently Nevada Power Supply Module

3500/15-04-00-00 | Bently Nevada Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : 3500/15-04-00-00

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 3500/15-04-00-00 Power Supply Module is a dedicated half-height power conversion unit engineered to energize the 3500 machinery protection system rack. This specific single-supply configuration features a low-voltage DC power supply occupying the top slot (04 option: 20 to 30 Vdc), leaves the bottom slot unpopulated (00 option), and omits specialized hazardous agency approvals (00 option). It converts external line voltages into stable internal power rails required by all installed monitor and interface modules.

Power Conversion and Architecture

The module occupies the specialized half-height slots on the left side of the 3500 chassis. Operating as a single-supply configuration in this specific ordering option, it delivers full electrical capacity to energize a completely populated rack of monitor cards and backplane interfaces.

The associated Power Input Module (PIM) mounts directly behind the supply to handle incoming low-voltage DC field wiring and provide robust input protection against line transients.

Input Regulation and Protection Features

The unit accepts a steady-state input voltage range of 20 to 30 Vdc, accommodating standard industrial control power variations. For out-of-range protection, minor under-voltage fluctuations will not harm the supply or the PIM, whereas severe over-voltage conditions safely trip the input protection components to isolate the rack.

A front-panel Supply OK LED illuminates green to provide instant visual verification of proper internal regulation and operational health.

Technical Parameters

Parameter Specification
Model 3500/15-04-00-00
Brand Bently Nevada
Series 3500 Machinery Protection System
Product Type Power Supply Module
Top Slot Supply Type 04 - Low Voltage DC (20 to 30 Vdc)
Bottom Slot Supply Type 00 - No supply (Single-supply configuration)
Agency Approval Option 00 - None
Operating Temperature -30 deg C to +65 deg C (-22 deg F to +150 deg F)
Storage Temperature -40 deg C to +85 deg C (-40 deg F to +185 deg F)
Operating Humidity 95%, non-condensing
Power Supply Module Dimensions 120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in)
Power Supply Module Weight 1.39 kg (3.06 lb)
Shipping Weight 5 kg

Frequently Asked Questions

Q: Can a second power supply be added later to this 3500/15-04-00-00 rack configuration?

A: Yes, the 3500 rack backplane supports dual power supply installation, allowing a secondary module to be added into the bottom slot for active backup redundancy.

Q: What input voltage range does the top slot module accept?

A: The low-voltage DC option accepts an input voltage ranging from 20 to 30 Vdc.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more