PRODUCT SKU : 330102-00-20-50-02-00

PRODUCT TYPE : Proximity Probes

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 330102-00-20-50-02-00 is an 8 mm proximity probe from the Bently Nevada 3300 XL series designed for non-contact vibration and relative position measurement in rotating machinery. This model features a 3/8-24 UNF mounting thread with integrated stainless-steel outer armor, a 0-inch unthreaded length, a 2-inch overall case length, and a 5.0-meter total cable length. It is equipped with a miniature coaxial ClickLoc connector and operates without requiring specialized hazardous-area agency approvals.

Mechanical Configuration and Suffix Breakdown

The base model 330102 designates an armored 3300 XL 8 mm proximity probe featuring a 3/8-24 UNF thread profile. The initial -00 option specifies a 0-inch unthreaded length, while the -20 option establishes a 2-inch overall case length for installation depth. The -50 code defines a total cable length of 5.0 meters (16.4 feet). The -02 option indicates a standard cable terminated with a miniature coaxial ClickLoc connector, and the final -00 code denotes that hazardous-area agency approvals are not required.

Technical Parameters

Parameter Specification
Model 330102-00-20-50-02-00
Brand Bently Nevada
Product Type 3300 XL 8 mm Proximity Probe
Thread Type 3/8-24 UNF with armor
Unthreaded Length Option 0 in (-00)
Overall Case Length Option 2 in (-20)
Total Length Option 5.0 metres (16.4 feet) (-50)
Connector and Cable-Type Option Miniature coaxial ClickLoc connector, standard cable (-02)
Agency Approval Option Not required (-00)
Weight 0.323 Kg
Shipping Weight 1.5 Kg
Country of Origin United States

Frequently Asked Questions

Q: Does this probe include protective cable armor?

A: Yes. The 330102 base model designation incorporates flexible stainless-steel outer armor over the cable assembly.

Q: What is the total cable length specified for this configuration?

A: The -50 option specifies a total cable length of 5.0 meters (16.4 feet).

Q: Does this model require hazardous-area agency certifications?

A: No. The terminal -00 suffix indicates that hazardous-area agency approvals are not required or included.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Designing Robust SCADA Systems for Electrical Substation Automation

Designing Robust SCADA Systems for Electrical Substation Automation

Electrical substation automation requires rigorous engineering standards to guarantee uninterrupted power distribution and grid stability. Therefore, control engineers must design supervisory control and data acquisition (SCADA) architectures with absolute precision. In my 15 years of commissioning power protection and substation automation systems, I have witnessed how meticulous SCADA design prevents catastrophic grid failures. Below, I outline the critical engineering practices required to build reliable substation SCADA solutions.

Read more
Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Industrial automation networks, power distribution systems, and complex control loops rely heavily on proper grounding to maintain operational integrity. Therefore, control engineers and electrical specialists must thoroughly understand the distinctions between earthing, grounding, and bonding. In my 15 years of commissioning distributed control systems (DCS) and factory automation architectures, I have encountered numerous mysterious equipment failures caused by improper grounding practices. Below, I clarify these essential concepts and outline the industry standards governing industrial electrical safety.

Read more
Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Industrial automation networks constantly generate vast streams of diagnostic data before major equipment failures occur. Therefore, integrating control systems with maintenance management platforms is essential for maximizing plant uptime. In my 15 years of commissioning programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) networks, I have witnessed how raw alarms sit unnoticed in controller buffers. Bridging the gap between automation software and computerized maintenance management systems (CMMS) transforms early warning signals into actionable work orders. Below, I examine how this integration drives predictive maintenance across modern industrial facilities.

Read more