Overview
The 22 100 from HIMA is a high-reliability safety-related output module designed for integration into safety-critical automation systems. It provides secure and monitored output channels for activating actuators, relays, and other field devices while maintaining compliance with stringent functional safety standards. This module ensures consistent and dependable operation in industrial safety environments.

Specifications

  • Model: 22 100

  • Brand: HIMA

  • Output Channels: 4–8 configurable safety output channels (depending on configuration)

  • Output Type: Relay or transistor (depending on module variant)

  • Output Voltage: 24V DC nominal

  • Output Current: Up to 2A per channel

  • Isolation: Channel-to-channel and channel-to-system galvanic isolation

  • Response Time: < 10 ms typical

  • Power Supply: 24V DC ±10%

  • Operating Temperature: -20°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Mounting: DIN rail compatible

  • Diagnostics: Built-in LED indicators per channel for status and fault detection

  • Compliance: SIL 2 / SIL 3 capable depending on system architecture

Features

  • Safety-certified output module for critical industrial applications

  • High-speed, monitored output channels for reliable actuation

  • Compact and modular design for easy integration into HIMA safety racks

  • Built-in diagnostic LEDs for fault detection and maintenance support

  • Designed for harsh industrial environments with wide temperature tolerance

Applications

Ideal for safety instrumented systems (SIS), emergency shutdown systems, process control systems requiring SIL-rated outputs, and integration into HIMA safety automation platforms.

FAQ

Q: How many outputs does the 22100 module support?
A: Configurable 4–8 safety output channels, depending on system setup.

Q: Is this module compatible with HIMA safety racks?
A: Yes, it integrates seamlessly with HIMA safety I/O racks.

Q: What types of outputs are supported?
A: Both relay and transistor outputs depending on module variant.

Q: What safety standards does the module comply with?
A: It supports SIL 2 / SIL 3 functional safety when integrated in a certified system architecture.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more