Skip to content

What are you looking for?


You may also like

140AVO02000 | Schneider Modicon Quantum Analog Output Module140AVO02000 | Schneider Modicon Quantum Analog Output Module140AVO02000 | Schneider Modicon Quantum Analog Output Module
140AVO02000 | Schneider Modicon Quantum Analog Output Module
140AVO02000 | Schneider Modicon Quantum Analog Output Module
140AVO02000 | Schneider Modicon Quantum Analog Output Module

140AVO02000 | Schneider Modicon Quantum Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 140AVO02000

PRODUCT TYPE : Hot Standby Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description:

The 140AVO02000 Analog Output Module is a high-performance solution from Schneider Electric designed for the Modicon Quantum automation platform. This module delivers precise analog output with versatile voltage and current configurations, ensuring reliable integration into industrial automation systems.

Key Features and Technical Specifications:

  • Product Type: Analog Output Module

  • Compatible Product Line: Modicon Quantum Automation Platform

  • Analog Output Channels: 4 channels

  • Addressing Requirement: 4 output words

  • Analog Output Range:

    • Bipolar Voltage: ±10 V (≥ 1000 Ω), ±5 V (≥ 500 Ω)

    • Unipolar Voltage: 0...10 V (≥ 1000 Ω), 0...5 V (≥ 500 Ω)

  • Analog Output Resolution: 12 bits

  • Analog Output Current: -10…10 mA

  • Source Resistance: 0.1 Ω

  • Maximum Cable Distance: 400 m (1312.3 ft)

  • Absolute Accuracy Error: ±0.15 % of full scale at 25 °C (77 °F)

  • Linearity: ±1 LSB

  • Accuracy Drift:

    • Unipolar: ±0.003 % of full scale/°C

    • Bipolar: ±0.004 % of full scale/°C

    • Maximum Unipolar: ±0.005 % of full scale/°C

    • Maximum Bipolar: ±0.007 % of full scale/°C

  • Channel Isolation: 500 V for 1 minute (47...63 Hz AC)

  • Bus Isolation: 780 V for 1 minute AC

  • Update Time: 3 ms

  • Settling Time: 700 µs to ±0.1 % of final value (maximum)

  • Bus Current Requirement: 700 mA

  • Power Dissipation: 4.5 W

  • Associated Fuse Rating: 0.063 mA 3 AG fast blow (250 V)

Local Signaling:

  • Green LED: Active bus communication

  • Red LED: External fault

  • Green LEDs (x4): Channel is turned on

  • Red LEDs (x4): Channel fault

Physical Characteristics:

  • Module Format: Standard

  • Net Weight: 0.7 lb (0.3 kg)

Application Scenarios:

The 140AVO02000 Analog Output Module is ideal for high-precision control in industrial automation systems where output signal accuracy is critical. It is used in:

  • Process control applications

  • Measurement and data acquisition systems

  • Automated manufacturing processes

FAQs:

Q: What voltage ranges can this module output?
A: The module supports both bipolar and unipolar voltage outputs, including ±10 V, ±5 V, and 0…10 V, 0…5 V configurations.

Q: How precise is the output?
A: The module features a 12-bit resolution and an accuracy of ±0.15% of full scale, ensuring reliable and consistent output.

Q: What is the maximum distance for connecting cables?
A: The module supports up to 400 meters (1312.3 ft) of cable length, providing flexibility for system design.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more