PRODUCT SKU : 3BHE009319R0001 UNS 2881B-P,V1

PRODUCT TYPE : Control Boards

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB UNS 2881b-P V1 3BHE009319R0001, also cataloged as the UNS 2881b-P V1 Control Boards, operates as a dedicated hardware component for high-speed signal processing and main unit interface routing within ABB power electronics and excitation subrack platforms.

Hardware Specifications

Parameter Specification
Model UNS 2881b-P V1 (Order Code: 3BHE009319R0001)
Brand ABB
Origin Switzerland
Weight 0.590 kg
Dimensions 255 mm x 28 mm x 31 mm (W x H x D)
Operating Temp 0 to +60 deg C
Power Consumption Powered via system subrack backplane bus supply
Assembly Description MUB PCB Completed
Customs Tariff 85371092
Product Type Control Boards

Firmware Flash Compatibility and High-Density Deterministic Execution

The UNS 2881b-P V1 printed circuit board assembly interfaces directly with host subrack backplanes to support deterministic signals across internal controller networks. Onboard component architecture maintains strict firmware flash compatibility with host excitation and converter software packages, preventing transmission latencies during real-time scan cycles across multi-node bus systems.

Frequently Asked Questions

Q: Can the UNS 2881b-P V1 circuit board be replaced while the subrack remains powered?

A: No. Auxiliary power supplies and backplane voltage must be fully de-energized prior to removing or inserting the printed circuit board to prevent backplane bus communication interruptions and electrical edge-connector damage.

Q: What grounding procedure should be followed when installing the UNS 2881b-P V1 board?

A: Ensure the board is firmly secured using factory mounting points to establish low-resistance electrical contact with the subrack chassis frame earth. Grounding integrity prevents noise interference on high-speed signal traces.

Field Installation Guidelines

  1. Power down the subrack chassis and ensure all energy storage elements have fully discharged.
  2. Align the UNS 2881b-P V1 PCB assembly with the designated subrack guide slots.
  3. Gently insert the board until backplane pin connectors are fully engaged with the mating bus receptacle.
  4. Fasten all panel retaining hardware to guarantee chassis frame grounding and mechanical stability.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more