Skip to content

What are you looking for?


You may also like

CP800 | ABB | Symphony Plus Communication Processor ModuleCP800 | ABB | Symphony Plus Communication Processor ModuleCP800 | ABB | Symphony Plus Communication Processor Module
CP800 | ABB | Symphony Plus Communication Processor Module
CP800 | ABB | Symphony Plus Communication Processor Module
CP800 | ABB | Symphony Plus Communication Processor Module

CP800 | ABB | Symphony Plus Communication Processor Module


Only 10 left - Selling fast

PRODUCT SKU : CP800

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB CP800, also cataloged as the CP800 Communication Processor Module, serves as the primary CP800 Central Unit utilized to execute network communication routing and interface logic across Symphony Plus platforms. The module manages data traffic between the central control network and foreign field subsystems, executing serial and Ethernet translation routines via backplane orchestration. Power distribution is managed through the chassis infrastructure, while an integrated 5 g lithium button cell battery secures operational memory registers and runtime clock configuration data during power supply interruptions.

Hardware Specifications

Parameter Specification
Model CP800
Brand ABB
Origin United States
Weight 0.99 kg
Dimensions 170.18 mm x 243.84 mm x 73.66 mm
Operating Temp 0 to +60 deg C (Standard industrial parameters apply)
Power Consumption Backplane bus dependent
Product Type Central Unit
Integrated Battery 1x Lithium Button Cell (5 g)
Environmental Compliance RoHS Directive 2011/65/EU / WEEE Category 5

Profinet / EtherNet/IP Deterministic Networks Mapping

The ABB CP800 utilizes native internal firmware blocks to map sub-signals into Profinet / EtherNet/IP deterministic networks, bypassing standard transit delays through hardware-level protocol acceleration. The module manages local communication stacks concurrently, matching network scan cycles to ensure synchronization with the master controller subassembly. This interface prevents jitter and maintains packet delivery intervals across the backplane network regardless of localized I/O density scaling.

Frequently Asked Questions

Q: How is memory retention managed on the CP800 during a complete power loss of the chassis base?

A: Memory allocation maps and volatile register variables are maintained by the internal 5 g lithium button cell battery. The battery retains power to the specific static RAM sectors until the backplane returns to normal voltage limits.

Q: Is hot-swapping permitted for this communication processor while the control network is active?

A: Hot-swapping is restricted by the redundancy topology of the slot configuration. In single-channel setups, removing the communication module drops the active network interface and triggers a peripheral connection timeout across the system architecture.

Q: What mechanisms ensure firmware flash compatibility when introducing a replacement CP800 module?

A: The master processing system scans the device hardware profile during power-up sequence validation. If a firmware mismatch is detected, the unit halts initialization to prevent unmapped protocol parameters from corrupting the active control network.

Field Installation Guidelines

The communication processor must be handled within an ESD-protected clean zone and aligned vertically with the card tracks on the modular chassis rack. Push the assembly into the backplane connectors until the mechanical latching hardware seats securely. The metallic housing of the rack must be grounded directly to the plant common ground grid via a low-impedance copper strap. Ensure that all field network lines are run inside separate grounded cable conduits to suppress external electrical interference profiles. Maintain a 50 mm space envelope around the perimeter of the chassis for convective thermal dissipation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more