Product Details

The ABB 3BSE019297R1 serves as the primary DSFR 197 Equipment Frame utilized to execute I/O module bus interfacing and physical structural housing across ABB Advant Master Control platforms. Integrated with a DSBB 172B Bus Back Plane, this hardware unit establishes mechanical alignment and backplane electrical connectivity for sub-rack process I/O cards. The frame provides passive structural support and direct backplane signal distribution without requiring active local processing circuits or internal battery power.

Hardware Specifications

Parameter Specification
Model DSFR 197 / DSRF 197
Product ID 3BSE019297R1
Brand ABB
Product Type Equipment Frames / Central Unit
System Platform ABB Advant Master Process Control System
Integrated Backplane DSBB 172B Bus Back Plane
Net Width 238.5 mm
Net Height 418.5 mm
Net Depth / Length 283.5 mm
Net Weight 8.1 kg
Operating Temp 0 to +55 deg C
Power Consumption Passive (Backplane line resistance negligible)
Internal Batteries 0 (None required)
Origin Sweden
RoHS Compliance Exempted per Article 2(4)(c), (e), (f), (j) of 2011/65/EU
WEEE Category Category 4 (Large Equipment > 50 cm)

Backplane Bus Interfacing and Power Distribution

The DSFR 197 framework integrates the DSBB 172B Bus Back Plane to establish high-velocity backplane bus communication and stable DC power routing across inserted I/O slots. High-density edge connectors ensure low contact resistance and structural pin alignment for sub-rack module insertion. Physical track separation on the DSBB 172B board minimizes inter-channel signal cross-talk during deterministic bus polling cycles. Firmware flash compatibility and bus address assignment are defined by the installed controller and peripheral modules connected directly to the multi-slot backplane bus structure.

Frequently Asked Questions

Q: Does the DSFR 197 equipment frame require active battery backup power?

A: No. The DSFR 197 frame contains zero internal batteries and operates purely as a mechanical carrier and passive backplane distribution assembly.

Q: What specific backplane printed circuit board is factory-installed in this equipment frame?

A: The frame comes pre-assembled with the DSBB 172B Bus Back Plane for internal communication routing and DC power bus distribution.

Q: What are the primary physical clearance requirements for housing the 3BSE019297R1 unit in a control cabinet?

A: Cabinet layout designs must account for physical frame dimensions of 238.5 mm width, 418.5 mm height, and 283.5 mm depth, leaving adequate vertical airflow clearance for natural thermal dissipation.

Field Installation Guidelines

  1. Verify panel cutout dimensions and cabinet mounting rack alignment prior to installing the 8.1 kg frame assembly.
  2. Secure the DSFR 197 frame to the cabinet rack using standard M6 mounting hardware, ensuring a minimum thread engagement of 5 full turns.
  3. Establish a low-impedance ground bonding link from the frame earth connection directly to the master cabinet protective earth (PE) bus.
  4. Inspect the DSBB 172B backplane pin headers for debris or physical misalignment before inserting hot-swappable I/O cards.
  5. Maintain segregated wiring paths for AC field supply cables and low-voltage DC backplane signal lines to avoid electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more