Skip to content

What are you looking for?


You may also like

ABB DSTA 001B 3BSE018316R1 Connection UnitABB DSTA 001B 3BSE018316R1 Connection UnitABB DSTA 001B 3BSE018316R1 Connection Unit
ABB DSTA 001B 3BSE018316R1 Connection Unit
ABB DSTA 001B 3BSE018316R1 Connection Unit
ABB DSTA 001B 3BSE018316R1 Connection Unit

ABB DSTA 001B 3BSE018316R1 Connection Unit


Only 10 left - Selling fast

PRODUCT SKU : DSTA 001B 3BSE018316R1

PRODUCT TYPE : Connection Units

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB DSTA 001B 3BSE018316R1, also cataloged as the DSTA 001B Connection Unit, operates as a dedicated hardware component for field signal termination and cable routing to the DSAX 110A analog board within ABB Advant Master Process Control System platforms.

Hardware Specifications

Parameter Specification
Model DSTA 001B 3BSE018316R1
Brand ABB
Origin Sweden
Weight 0.222 kg
Dimensions 540 mm x 30 mm x 335 mm
Operating Temp 0 to +55 deg C (Standard Industrial Range)
Power Consumption Passive Hardware Termination
Target Board Compatibility DSAX 110A Analog Board
Product Type Connection Unit / I-O Module

Backplane Bus Communication Velocity & I/O Density Scaling

The connection unit facilitates physical signal passthrough from field cabling to primary controller backplanes. Optimized contact path traces preserve signal integrity across high-density I/O configurations. System-level synchronization maintains deterministic network scan execution, while physical design integrity ensures backplane bus communication velocity and firmware flash compatibility remain uncompromised throughout high-speed analog loop sampling.

Frequently Asked Questions

Q: Which analog board is designed to interface directly with the DSTA 001B termination unit?

A: The DSTA 001B is designed specifically as the physical connection unit for the DSAX 110A analog board.

Q: Does the DSTA 001B connection unit consume active backplane current?

A: No, the connection unit functions as a passive physical termination and interface board, relying on the host rack supply for signal path continuity.

Field Installation Guidelines

  • Isolate field loop power and controller backplane power prior to attaching ribbon cables or wiring field connections to the unit.
  • Securely mount the 540 mm chassis to panel mounting rails using standard fasteners to ensure vibration stability.
  • Connect all cable shield braids directly to a low-impedance protective earth (PE) ground bar to prevent noise interference on analog signal lines.
  • Verify keyed header connector alignment when connecting the ribbon harness to the DSAX 110A analog board to prevent pin bending.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more