Description

The TK811V050 3BSC950107R2 is a 5.0-meter optical cable for ABB System 800xA, designed for distributed I/O stations requiring optical isolation. It enables physical separation of I/O clusters across cabinets or enclosures, using POF technology to provide galvanic isolation and protect against ground loops and high-voltage transients. The rugged cable is factory-terminated with precision connectors for secure, low-loss connections to S800 communication ports. Its flexibility and EMI resistance make it ideal for reliable real-time control in power plants and factories.

Specifications

  • Manufacturer: ABB

  • Model Number: TK811V050 (3BSC950107R2)

  • Product Type: Plastic Optical Fiber (POF) Cable

  • Length: 5.0 meters

  • Channel Configuration: Duplex (Transmit/Receive)

  • Fiber Core: 980/1000 µm Polymethyl Methacrylate (PMMA)

  • Communication Link: S800 Optical ModuleBus

  • Protection: Industrial-grade flame-retardant jacket

  • Connector Type: Snap-in optical connectors

  • Weight: 0.15 kg

Features

  • Extended Inter-Cluster Reach: The 5m length facilitates the connection of remote I/O clusters, allowing for flexible distributed architecture within large control rooms.

  • Inherent EMI/RFI Immunity: Light-based transmission is unaffected by motors, drives, or switchgear, ensuring deterministic data flow in noisy electrical environments.

  • Zero-Voltage Potential Link: Provides absolute electrical separation between connected clusters, safeguarding sensitive hardware from surges and lightning-induced transients.

  • High Mechanical Flexibility: Features a tighter bend radius compared to glass fiber, allowing for easier routing through narrow cable ducts and around corners.

  • Plug-and-Play Reliability: Factory-polished connectors guarantee optimal signal coupling and high-retention physical security in high-vibration applications.

  • Scalable I/O Architecture: Designed for native integration with S800 optical interfaces, supporting the rapid expansion of System 800xA distributed networks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more