{"product_id":"woodward-5464-648-analog-output-module","title":"Woodward 5464-648 Analog Output Module","description":"\u003cp\u003eConfigured for precision signal output in gas turbine control platforms, the \u003cstrong\u003eWoodward 5464-648\u003c\/strong\u003e (\u003cstrong\u003e5464-648\u003c\/strong\u003e Analog 8-Channel Output Module) provides direct physical\/electrical execution of 4-20 mA and voltage control signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5464-648\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 x 16 x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 Independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus, Profibus, EtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe 5464-648 module utilizes high-resolution digital-to-analog conversion to facilitate precise positioning of turbine inlet valves and actuators. Each of the eight channels operates independently, allowing for granular control of auxiliary gas turbine components. The response characteristics of the actuator control loop are governed by the host controller's scan cycle and the module's internal conversion latency. To ensure loop stability, output signals must be monitored via the control system's feedback inputs, confirming the mechanical position of the valve aligns with the commanded current or voltage output.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 5464-648 capable of hot-swapping within the control rack?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping capabilities are dependent on the specific turbine control rack backplane architecture. Refer to the primary system documentation to determine if the power-up state of the module upon re-insertion will cause an unintended actuator movement.\u003c\/p\u003e\n\u003cp\u003eQ: Are the analog outputs galvanically isolated from the communication backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module supports standard industrial integration. It is recommended to employ signal isolators if the field actuator loops share a common potential with high-noise electrical equipment or if ground loops are identified during commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting:\u003c\/strong\u003e Ensure the module is properly aligned with the chassis connectors before engagement. Use the provided extraction mechanism to seat the module firmly into the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e Utilize shielded, twisted-pair cabling for all 4-20 mA analog output runs to mitigate electromagnetic interference. Ground the cable shield at the control cabinet side only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Verification:\u003c\/strong\u003e Prior to enabling the control software, use a calibrated process meter to verify the signal output at the field terminal blocks for each of the eight channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the manufacturer-provided software tools to define the output scaling for each channel and confirm that the register mapping matches the host controller (PLC\/DCS) memory map.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53002096116021,"sku":"5464-648","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5464-648.png?v=1781505578","url":"https:\/\/www.5gplc.com\/ru\/products\/woodward-5464-648-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}