{"product_id":"nfsb100-s00-yokogawa-esb-bus-repeat-module","title":"NFSB100-S00 | Yokogawa | ESB Bus Repeat Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFSB100-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-speed Bus Repeat Module designed to extend the physical reach of the internal system bus. It receives communication signals from one bus segment, regenerates them to eliminate degradation, and re-transmits them to the next segment with full signal strength. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the essential hardware needed to maintain deterministic performance across large-scale distributed control systems (DCS).\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100-S00 follows a standard Yokogawa identification structure for bus interface hardware:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFSB100:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB Bus Repeat Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard hardware configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic type (Always 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard specification without additional options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100-S00 maintains strict synchronization across multiple bus segments within its compact frame.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Regeneration and Bus Extension\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProprietary Internal System Bus (ESB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mm x 100 mm x 42 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActive Jitter Cleaning and Amplification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Network Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NFSB100-S00 overcomes the physical distance limitations inherent in single bus segments. It allows engineers to place remote I\/O stations significantly further from the central controller, facilitating large-scale plant layouts without compromising communication speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Data Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module cleans up signal noise and boosts strength during the re-transmission process. This active regeneration ensures that the control system retains high-fidelity data, even as the network expands to include additional nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSegment Isolation for Fault Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module incorporates electrical isolation between bus segments. This architecture prevents a local cable fault or electrical surge on one segment from propagating through the entire network, protecting the central CPU and ensuring continuous operation of unaffected zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimal Latency Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile repeaters typically introduce delays, the NFSB100-S00 utilizes optimized circuitry to minimize signal propagation time. This ensures that the control network maintains the strict determinism required for high-speed safety and process loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NFSB100-S00 support redundant bus configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In systems implementing a redundant control bus, you typically install two NFSB100-S00 modules to maintain high availability over extended distances. This setup ensures that if one repeater or bus line fails, the secondary path maintains the communication link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many nodes can I add by using this repeat module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module removes the physical signal limitations for distance, but you must still adhere to the maximum node count defined by your specific Yokogawa system software (e.g., CENTUM VP). Consult your system configuration manual to verify the total addressable capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the installation procedure for the NFSB100-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module installs into a dedicated slot within the control station. Ensure you power down the target segment before insertion and verify that all bus cables use the correct termination resistors to prevent signal reflection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the authenticity of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe offer only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Yokogawa factory-sealed packaging. Every module features a unique, verifiable serial number and the manufacturer's quality control stamp, ensuring it meets all factory specifications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551111770421,"sku":"NFSB100-S00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFSB100-S50_0abfd342-7052-4af0-a818-313c0100caea.jpg?v=1775728056","url":"https:\/\/www.5gplc.com\/ru\/products\/nfsb100-s00-yokogawa-esb-bus-repeat-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}