{"product_id":"yokogawa-aai143-s53-k4a00-centum-vp-isolated-analog-input-module","title":"Módulo de Entrada Analógica Yokogawa AAI143-S53\/K4A00","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI143-S53\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a versatile 16-channel isolated analog input interface for the CENTUM VP production control system. It accurately captures 4 to 20 mA signals from field transmitters and converts them into high-resolution digital data. This specific configuration features ISA G3 environmental hardening and a KS cable interface, making it the primary choice for mission-critical loops in corrosive or demanding industrial atmospheres.\u003c\/p\u003e\n\u003ch2\u003ePart Number Breakdown: AAI143-S53\/K4A00\u003c\/h2\u003e\n\u003cp\u003eYokogawa's alphanumeric coding defines the specific hardware capabilities and protection levels:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAAI143:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase Model for Isolated Analog Input (4 to 20 mA, 16-channel).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard switch-over response for redundant configurations; no explosion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA Standard G3 compliant with an extended temperature range of -20 to 70 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/K4A00:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKS cable interface adapter designed for connection to AEA4D terminal boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eWe supply this module in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure immediate system compatibility and longevity.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 channels, fully isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e 16 \u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003eA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower ON: 270 \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e (20mA) to 350 \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e (4mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.0 V or higher (at 20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Drift\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e 16 \u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003eA \/ 10 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 mA (5 V DC), 540 mA (24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC between input and system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Wire Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features physical setting pins for each channel. This allows engineers to toggle between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire and 4-wire transmitter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurations independently, providing maximum flexibility during field instrument integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-level isolation (1500 V AC) prevents field-side electrical noise and ground loops from affecting the DCS backplane. The 10 ms update period ensures the control system receives real-time data for high-speed PID loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe G3 conformal coating allows the module to withstand harsh chemical environments, such as those found in paper mills or petrochemical refineries, preventing premature circuit failure due to atmospheric sulfur or moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen used in a redundant pair, the AAI143-S53 executes a seamless switch-over. If the active module detects a fault, the standby unit takes over the signal processing without interrupting the 4-20 mA loop or causing a process bump.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the module for a 4-wire transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must set the specific pin on the module side for the corresponding channel. This disconnects the internal transmitter power supply from that channel, allowing it to safely receive signals from externally powered 4-wire instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the \/K4A00 option require a specific cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the \/K4A00 adapter is designed to interface with Yokogawa KS cables. This setup typically connects the module to an AEA4D or similar terminal board, streamlining cabinet wiring and reducing the risk of manual termination errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the AAI143-S53 operate in sub-zero environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The \"-3\" suffix confirms the hardware remains operational down to -20 °C, making it suitable for unheated control rooms or outdoor-mounted enclosures in cold climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the input resistance when the module loses power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen power is OFF, the input resistance increases to 500 k$\\Omega$ or larger. This high impedance ensures the module does not load down the field loop or interfere with other devices in the circuit during a power failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52467864830261,"sku":"AAI143-S53\/K4A00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AAI143-S53_867d7eb4-eb3a-4148-a5a6-b72ecaf5a8e4.jpg?v=1774252994","url":"https:\/\/www.5gplc.com\/pt\/products\/yokogawa-aai143-s53-k4a00-centum-vp-isolated-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}