{"product_id":"mvi56e-mnetc-prosoft-modbus-tcp-ip-multi-client-communication-module","title":"MVI56E-MNETC | Módulo de Comunicação Multi-Cliente ProSoft Modbus TCP\/IP","description":"\u003ch3\u003e\u003cstrong\u003eDescrição do Produto\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eda ProSoft é um módulo avançado de interface multi-cliente\/servidor Modbus TCP\/IP desenvolvido para a plataforma Allen-Bradley ControlLogix. Projetado para ocupar um único slot no chassi ControlLogix, oferece conectividade perfeita para redes industriais de grande escala e sistemas de controle de processos.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePrincipais Características\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSuporta processadores ControlLogix versão 10 ou superior\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGerencia até 30 clientes Modbus TCP e 20 servidores Modbus TCP simultaneamente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMapeamento de memória definível pelo usuário com suporte a 10.000 registradores de 16 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguração via Instruções Adicionais (AOI) e lógica ladder de exemplo para implantação rápida\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePorta de comunicação RJ45 única com taxa de dados de 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatível com racks locais ou remotos\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTipo de transferência de dados em lógica ladder para controle preciso\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eEspecificações Técnicas\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModelo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarca:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProSoft \/ Allen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarga de Corrente no Backplane:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e800 mA @ 5 VDC; 3 mA @ 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperatura de Operação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C a 60°C (32°F a 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperatura de Armazenamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C a 85°C (-40°F a 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistência a Choques na Operação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuporta 30 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUmidade Relativa:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% a 95% (sem condensação)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTamanho do Slot:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSlot único\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTamanho dos Dados:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAté 10.000 palavras com registradores de 16 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eAplicações\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal para automação industrial, controle de processos e redes PLC de grande escala onde múltiplos clientes e servidores Modbus TCP precisam de comunicação simultânea e confiável.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePerguntas Frequentes\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eP: Quantos clientes Modbus este módulo pode suportar?\u003c\/strong\u003e\u003cbr\u003eR: Até 30 clientes Modbus TCP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Qual é a memória máxima de dados suportada?\u003c\/strong\u003e\u003cbr\u003eR: 10.000 registradores de 16 bits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP: Quais processadores ControlLogix são compatíveis?\u003c\/strong\u003e\u003cbr\u003eR: Versões 10 ou superiores.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52395648876853,"sku":"MVI56E-SIE","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MVI56E-AFC_5dbec910-3c18-4bd5-aaad-ce189380f977.jpg?v=1772519161","url":"https:\/\/www.5gplc.com\/pt\/products\/mvi56e-mnetc-prosoft-modbus-tcp-ip-multi-client-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}