{"product_id":"abb-spau330-c1-aa-combined-overvoltage-and-undervoltage-relay","title":"Relé Combinado de Sobretensão e Subtensão ABB SPAU330 C1-AA","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescrição\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eO \u003cstrong\u003eSPAU330 C1-AA\u003c\/strong\u003e protege subestações monitorando as tensões entre fases e detectando condições de sobretensão ou subtensão. Ele fornece disparos rápidos e precisos com temporização programável, protegendo motores, geradores e transformadores contra falhas e instabilidade da rede.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eEspecificações\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eFabricante:\u003c\/b\u003e\u003cspan class=\"\"\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003ePaís de Origem:\u003c\/b\u003e\u003cspan class=\"\"\u003e Suíça\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eNúmero do Modelo:\u003c\/b\u003e\u003cspan class=\"\"\u003e SPAU330 C1-AA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSérie do Produto:\u003c\/b\u003e\u003cspan class=\"\"\u003e SPACOM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eTipo de Módulo:\u003c\/b\u003e\u003cspan class=\"\"\u003e Relé de Proteção de Tensão Combinada\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eFrequência Nominal:\u003c\/b\u003e\u003cspan class=\"\"\u003e 50 Hz ou 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eAlimentação Auxiliar:\u003c\/b\u003e\u003cspan class=\"\"\u003e 110-240 V AC\/DC ou 24-60 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePeso Aproximado:\u003c\/b\u003e\u003cspan class=\"\"\u003e 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePadrão:\u003c\/b\u003e\u003cspan class=\"\"\u003e Conformidade IEC 60255\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eCaracterísticas\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eLógica Multi-Estágio:\u003c\/b\u003e\u003cspan class=\"\"\u003e Possui estágios independentes de baixo e alto ajuste para monitoramento tanto de sobretensão quanto de subtensão,\u003c\/span\u003e\u003cspan class=\"\"\u003e permitindo esquemas de proteção graduada precisos.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eCaracterísticas de Tempo Selecionáveis:\u003c\/b\u003e\u003cspan class=\"\"\u003e Suporta tanto atrasos de tempo definidos quanto curvas inversas de tempo mínimo definido (IDMT) para atender a requisitos específicos de carga.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eRegistro de Dados de Falha:\u003c\/b\u003e\u003cspan class=\"\"\u003e Inclui memória não volátil para registro de valores de disparo e duração,\u003c\/span\u003e\u003cspan class=\"\"\u003e auxiliando na análise rápida pós-falha.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSistema de Auto-Supervisão:\u003c\/b\u003e\u003cspan class=\"\"\u003e Funcionalidade integrada de watchdog verifica continuamente a integridade do hardware e software interno para garantir alta disponibilidade.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eIntegração de Protocolo:\u003c\/b\u003e\u003cspan\u003e Equipado com uma interface de comunicação SPA-bus para aquisição remota de dados e conectividade com sistema SCADA.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52103616332085,"sku":"SPAU330 C1-AA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/SPAU330C1-AA__1.jpg?v=1766988775","url":"https:\/\/www.5gplc.com\/pt\/products\/abb-spau330-c1-aa-combined-overvoltage-and-undervoltage-relay","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}