{"product_id":"yokogawa-sai533-h03-s1-analog-output-module","title":"Yokogawa SAI533-H03-S1 Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SAI533-H03-S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSAI533\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for 4-20 mA loop signaling and actuator control execution within CENTUM VP control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSAI533\u003c\/strong\u003e: Base 8-channel 4-20 mA analog output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-H03\u003c\/strong\u003e: Standard signal performance specification with HART communication support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-S1\u003c\/strong\u003e: Single \/ standard module configuration code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAI533-H03-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C (Standard industrial limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 320 mA at 5 V VDC system backplane, Max. 300 mA at 24 VDC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Range\u003c\/td\u003e\n\u003ctd\u003e1.25 to 23 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e230 to 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-48 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Frequency\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV AC between output channels and system for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; HART Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe SAI533-H03-S1 architecture maintains dynamic signal integrity across its 8 isolated output channels using a superimposed 4-20 mA HART loop protocol. Internal digital-to-analog converter loops process real-time updates every 40 ms while channel-to-channel isolation eliminates common-mode ground loop distortion. High-precision output circuitry limits thermal drift to +\/-16 uA per 10 deg C, maintaining calibrated accuracy across changing ambient cabinet temperatures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane and external voltage rail current consumption limits for the SAI533-H03-S1?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum current of 320 mA from the internal 5 V VDC system backplane bus and up to 300 mA from the external 24 VDC field power rail.\u003c\/p\u003e\n\u003cp\u003eQ: What load resistance range is supported on each analog output channel?\u003c\/p\u003e\n\u003cp\u003eA: Each individual channel operates within an allowable field loop load resistance range of 230 to 600 Ohm.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation rating protects system-side logic from field-side voltage spikes?\u003c\/p\u003e\n\u003cp\u003eA: The galvanic isolation barrier between the output terminals and internal backplane system circuitry is rated to withstand 1.5 kV AC for 1 minute.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion \u0026amp; Backplane Engagement\u003c\/strong\u003e: Ensure the system rack power is off or verify hot-swap compatibility rules for the specific node unit before inserting the module. Seat the module firmly into the slot until the retaining latches click into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring \u0026amp; Shielding\u003c\/strong\u003e: Route twisted-pair shielded field cables away from high-voltage AC lines. Connect the overall cable shield to the cabinet earthing bar at a single terminal point to prevent ground loop currents from interfering with current outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit and Environmental Protection\u003c\/strong\u003e: Seal field wiring conduit entries to prevent dust and corrosive gases from entering the terminal block area. Verify that channel load loop impedances remain between 230 and 600 Ohm prior to powering the field circuit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53439387599157,"sku":"SAI533-H03-S1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/SAI533-H03.png?v=1788248406","url":"https:\/\/www.5gplc.com\/products\/yokogawa-sai533-h03-s1-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}