{"product_id":"yokogawa-np1-c-input-output-module","title":"Yokogawa NP1*C Input\/Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NP1*C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNP1\u003c\/strong\u003e Input\/Output Module, operates as a dedicated hardware component for field signal processing and system interface execution within Yokogawa PLC platforms. The module interfaces analog and digital field signals with controller memory over system backplane connections, utilizing 512 KB to 4 MB RAM and 256 KB to 2 MB Flash ROM for onboard data buffering and program storage. Communication lines support RS-232, RS-485, and Ethernet physical layers to execute program control logic written in ladder logic, function block, or structured text.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNP1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model designation for PLC modular processor and I\/O series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003cstrong\u003eC\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eStyle code Revision C indicating hardware revision and internal circuit design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNP1*C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 100 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ backplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e512 KB to 4 MB RAM, 256 KB to 2 MB Flash ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Languages\u003c\/td\u003e\n\u003ctd\u003eLadder logic, function block, structured text\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eModular (analog and digital options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and DCS Process Integration\u003c\/h3\u003e\n\u003cp\u003eThe NP1*C module processes 4-20 mA HART loop protocol parameters alongside discrete digital field inputs. To maintain signal accuracy across mixed instrument loops, channel-to-channel isolation circuits suppress electrical cross-talk and ground loop currents between field wiring and internal processing buses. Thermal input channels incorporate cold junction compensation (CJC) processing to ensure precise temperature signal conversion. Fieldbus data received over RS-485 or Ethernet networks are mapped directly into system memory, ensuring real-time execution of function block control routines without bus contention.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle programming logic execution and memory allocation?\u003c\/p\u003e\n\u003cp\u003eA: Control program routines written in ladder logic, function block, or structured text reside in the 256 KB to 2 MB Flash ROM. Active process variables and scan cycle runtime data are stored within the 512 KB to 4 MB RAM space.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding and shielding methods protect serial communication over RS-485 lines?\u003c\/p\u003e\n\u003cp\u003eA: RS-485 network cables require shielded twisted-pair conductors with the shield braid bonded directly to the cabinet functional earth bus bar at a single termination point to prevent noise coupling.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for the NP1*C module on active PLC subracks?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping depends on the specific baseplate slot configuration; power down the local slot or subrack prior to module extraction unless redundant backplane power and bus isolation are active.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Align the NP1*C module with the guide rails in the designated PLC slot. Push firmly until the backplane connectors latch into place, and tighten retaining screws to secure the chassis against mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-voltage RS-232, RS-485, and Ethernet communication cables in separate wire channels from high-voltage AC power lines to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the main rack assembly to a low-impedance earth ground plane. Cable shields for serial and Ethernet connections must terminate at designated grounding lugs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain clear air ventilation channels above and below the module housing (100 mm x 100 mm x 50 mm) to ensure natural convection keeps the operating ambient temperature between -25 deg C and 70 deg C.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53281674821941,"sku":"NP1*C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NP1C.png?v=1786689498","url":"https:\/\/www.5gplc.com\/products\/yokogawa-np1-c-input-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}