{"product_id":"yokogawa-nfbu200-s10-prosafe-rs-base-module-style-s1","title":"Yokogawa NFBU200-S10 ProSafe-RS Base Module Style S1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFBU200-S10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the foundational structural component for the ProSafe-RS safety instrumented system. This base module provides the physical backplane and communication bus required to house and interconnect safety CPUs and I\/O modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, offering a critical solution for maintaining or expanding existing safety control stations where the manufacturer has transitioned to newer series.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFBU200\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Control Station Base Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle S1 Hardware Revision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports 19-inch Rack and DIN rail options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19-inch Rack Mount \/ DIN Rail Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSafe-RS Safety Instrumented Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC Module \/ Rack Infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.20 lbs (Approx. 0.54 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Industrial Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Mounting Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NFBU200-S10 supports both standard 19-inch rack installation and DIN rail mounting. This flexibility allows engineers to integrate the safety station into existing server-style racks or compact field-mount marshalling cabinets without modifying the enclosure infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Backplane:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a high-reliability bus structure to ensure deterministic communication between safety modules. This architecture prevents signal latency, ensuring the safety system executes shutdown logic within the required millisecond timeframes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance for Legacy Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a factory-new original unit, this base module replaces aged or damaged racks in discontinued ProSafe-RS installations. It restores the physical integrity of the control station, eliminating the intermittent bus errors often caused by oxidized connectors in older, used equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Mechanical Framework:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe frame withstands the mechanical stresses of fully loaded I\/O configurations. Its lightweight yet rigid construction facilitates easy handling during installation while providing a stable platform for heavy-duty safety CPUs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I still procure the NFBU200-S10 if the manufacturer has discontinued it?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock specifically for the B2B industrial market. This allows you to repair or expand your current ProSafe-RS system without the massive capital expenditure required for a total system migration to the latest series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Style S1 and other revisions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStyle S1 denotes the specific internal bus architecture and connector positioning. Always verify that your existing modules (CPUs and I\/O) match the S1 physical layout to ensure a proper fit and reliable electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this rack include the power supply modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The NFBU200-S10 provides the mechanical base and backplane. You must purchase the compatible power supply modules, CPUs, and I\/O modules separately to complete the safety control station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many modules does this base unit accommodate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis standard 19-inch rack version typically follows the standard ProSafe-RS slot configuration. Please refer to your specific system topology to determine the exact number of I\/O or processor modules permitted per base unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777676505397,"sku":"NFBU200-S10","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFBU200-S101.png?v=1776927621","url":"https:\/\/www.5gplc.com\/products\/yokogawa-nfbu200-s10-prosafe-rs-base-module-style-s1","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}