{"product_id":"yokogawa-f3yd14-0n-fa-m3-transistor-output-module","title":"Yokogawa F3YD14-0N FA-M3 Transistor Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3YD14-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-capacity digital output interface for the FA-M3 multi-controller series. This module provides 14 transistor sink-type outputs, specifically engineered to drive high-current DC loads such as large solenoids, hydraulic valves, and heavy-duty contactors. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak switching performance and long-term thermal stability in mission-critical automation loops.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF3YD14\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-Point Transistor Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuffix\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnhanced thermal\/current capacity revision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransistor Contact (Sink Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 points per common\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per point (14 A per common total)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms max. (OFF to ON \/ ON to OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eON Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 V DC max.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeakage Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 mA max. (at OFF state)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Active Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-point terminal block (M3.5 screws)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard PLC output modules that limit current to 0.5A, the F3YD14-0N supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2A per point\u003c\/strong\u003e. This allows direct control of power-hungry field devices without the need for interposing relays, reducing cabinet complexity and failure points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Switching Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transistor circuitry achieves a response time of less than\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 ms\u003c\/strong\u003e. This deterministic performance facilitates high-speed synchronized operations in packaging, bottling, and motion control applications where millisecond precision dictates throughput.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Inductive Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery output channel incorporates an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eActive Clamp surge protector\u003c\/strong\u003e. This feature actively suppresses the back-EMF generated during the de-energization of inductive loads, shielding the internal semiconductors from voltage spikes and ensuring a long hardware lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe Logic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides a configurable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHOLD\/RESET\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction for CPU errors. Engineers can define whether each of the 14 points maintains its current state or resets to zero during a controller fault, preventing hazardous machine movements during system interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware operates reliably across a wide temperature gradient of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-20 to 65°C\u003c\/strong\u003e. This makes the F3YD14-0N suitable for non-climate-controlled environments and outdoor enclosures where standard electronics might suffer from thermal drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix 12V and 24V DC loads on the same common?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module shares a single common for all 14 points. Therefore, you must use a consistent rated load voltage (either 12V or 24V DC) across the entire terminal block to prevent electrical interference or hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the sink-type output affect my wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a sink-type (NPN) module, the F3YD14-0N connects the load to the negative terminal (OV) when activated. You must connect the other side of your field device to the positive supply voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 14A common rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile each point can handle 2A, the total simultaneous current for all 14 points must not exceed 14A due to the thermal limits of the common terminal. Always calculate your total load budget to ensure it falls within this 14A threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external power supply for logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module requires an external 12 to 24 V DC (10mA) supply to power the output driving circuitry, in addition to the 100mA it draws from the internal 5V DC PLC backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777705603381,"sku":"F3YD18-0N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3YD14-0N.png?v=1776928600","url":"https:\/\/www.5gplc.com\/products\/yokogawa-f3yd14-0n-fa-m3-transistor-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}