{"product_id":"yokogawa-f3da04-6r-fa-m3-high-resolution-analog-i-o-module","title":"Yokogawa F3DA04-6R FA-M3 High-Resolution Analog I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3DA04-6R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance analog interface for the FA-M3 multi-controller series. This module integrates high-resolution 16-bit Analog-to-Digital conversion to manage critical process variables with extreme precision. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the ultra-fast sampling speeds required for advanced machine control and high-speed data acquisition.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Bit High-Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 VDC, -10 to 10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA, 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePC Board PLC \/ Add-On Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3DA04-6R executes sampling at a rate of 50\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es per point. This speed allows the PLC to capture transient signal spikes and rapid process fluctuations that standard analog modules typically miss, making it ideal for high-speed pressure monitoring or motion feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior 16-Bit Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit ADC architecture provides 65,536 levels of quantization. This high granularity ensures the control system detects minute changes in sensor data, which directly improves the accuracy of PID loops and delicate chemical dosing processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Signal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module accepts multiple signal types, including bipolar voltage (-10 to 10 VDC) and standard process currents (4 to 20 mA). Engineers configure these ranges to match various field instruments without requiring external signal conditioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"6R\" revision incorporates advanced filtering circuitry to mitigate electromagnetic interference (EMI). This hardware-level protection prevents data corruption in harsh plant environments where high-frequency noise from VFDs or heavy machinery often distorts sensitive analog signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F3DA04-6R require a specific base unit for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3DA04-6R fits standard FA-M3 I\/O slots. However, to utilize the 50\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es sampling speed effectively, ensure your CPU module supports high-speed bus communication to prevent data bottlenecks at the processor level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between voltage and current input modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou select the input range and mode via the PLC configuration software. Additionally, ensure you wire the terminals according to the specific voltage or current diagram provided in the Yokogawa technical manual to engage the internal precision resistors for current loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for legacy system replacements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We provide these units as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock to replace failing or aging modules in existing FA-M3 racks. Replacing a worn module with a new F3DA04-6R restores factory-spec accuracy and system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use all 4 points for different signal ranges simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module allows independent configuration for its input points. This enables you to monitor a 4-20mA flow meter on one channel while simultaneously tracking a -10V to +10V position sensor on another.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777501262133,"sku":"F3DA04-6R","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3DA04-6R.png?v=1776916890","url":"https:\/\/www.5gplc.com\/products\/yokogawa-f3da04-6r-fa-m3-high-resolution-analog-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}