{"product_id":"yokogawa-cr5-pa-a-temperature-input-module","title":"Yokogawa CR5-PA*A Temperature Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa CR5-PA*A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCR5-PA\u003c\/strong\u003e Temperature Input Module, operates as a dedicated hardware component for temperature signal conditioning and 8-channel field input processing within CENTUM CS 3000 and AS-E9730CA-03 platforms. It converts field thermocouple or RTD inputs and provides 8 output channels while handling protocol conversion to internal serial and CAN field buses.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCR5-PA*A (CR5-PA Suffix A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mount standard enclosure dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUp to 6 W (typical, depending on configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Temperature Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Data Rate\u003c\/td\u003e\n\u003ctd\u003e1 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000, AS-E9730CA-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation (CJC) and Process Control Instrumentation\u003c\/h3\u003e\n\u003cp\u003eThe CR5-PA*A incorporates cold junction compensation (CJC) reference circuits across its 8 temperature input channels to maintain accurate thermal emf conversion during ambient temperature fluctuations. Designed to stream real-time thermal telemetry into Yokogawa process control platforms, the module processes analog input signals and formats process variables for transmission over Modbus RTU and CANopen networks at data rates up to 1 Mbps. Internal channel-to-channel isolation and signal conditioning circuits protect backplane communications from field-side ground loops and common-mode noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication protocols are supported by the CR5-PA*A module for data transmission?\u003c\/p\u003e\n\u003cp\u003eA: The module supports Modbus RTU and CANopen protocols, achieving maximum network data rates of up to 1 Mbps.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power consumption profile of the CR5-PA*A during operation?\u003c\/p\u003e\n\u003cp\u003eA: Typical power consumption is up to 6 W, depending on active channel usage and output signal configuration.\u003c\/p\u003e\n\u003cp\u003eQ: How is the CR5-PA*A module physically mounted within a control cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed with an integrated mounting mechanism for standard industrial DIN rail installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded anti-static wrist strap when handling the module assembly to prevent damage to sensitive internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Hook the top mounting latch onto the 35 mm DIN rail and push the module downward until the bottom spring clip locks securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminate temperature sensor cable drain wires to a single dedicated instrument earth bar to prevent circulating ground currents from compromising measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-voltage temperature input leads away from AC power lines and high-current motor cables inside cabinet wire ducts to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53312648380725,"sku":"CR5-PA*A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CR5-PAA.png?v=1786947420","url":"https:\/\/www.5gplc.com\/products\/yokogawa-cr5-pa-a-temperature-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}