{"product_id":"yokogawa-cp332d-power-supply-module","title":"Yokogawa CP332D Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa CP332D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP332D\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for direct AC to DC conversion and regulated DC voltage distribution within Yokogawa industrial control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP332D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 110 mm x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2 A max at 100 VAC to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 V to 32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 A to 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple and Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mVp-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100 VAC to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CP332D integrates internal line-side galvanic isolation to insulate low-voltage DC logic and field buses from AC power mains transients. Within Yokogawa process automation sub-racks hosting 4-20 mA HART loop protocol transmitters and I\/O cards, the module maintains tight line and load regulation (+\/-0.05%) while output ripple and noise are suppressed under 100 mVp-p. This regulation performance mitigates common-mode electrical interference across process measurement channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the output voltage and current controlled remotely on the CP332D?\u003c\/p\u003e\n\u003cp\u003eA: Parameter adjustment and real-time status monitoring are executed via the integrated RS-232C serial communication interface.\u003c\/p\u003e\n\u003cp\u003eQ: What protective features are built into the CP332D output circuit?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates internal overvoltage, overcurrent, and short-circuit protection circuits to halt output generation during electrical faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded anti-static wrist strap during module installation and terminal wiring to prevent electrostatic discharge damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Line Isolation:\u003c\/strong\u003e Ensure main AC supply lines are de-energized and locked out before wiring conductors to input power terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Earthing:\u003c\/strong\u003e Connect the designated protective earth (PE) ground terminal to the main enclosure grounding bus via a short, low-impedance copper lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route AC power input cables in separate conduits away from sensitive low-voltage DC output lines and signal buses to avoid inductive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53312754549045,"sku":"CP332D","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CP332D.png?v=1786951602","url":"https:\/\/www.5gplc.com\/products\/yokogawa-cp332d-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}