{"product_id":"yokogawa-asi533-h00-centum-vp-8-channel-isolated-analog-input-module","title":"Yokogawa ASI533-H00 CENTUM VP 8-Channel Isolated Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ASI533-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-density, 8-channel isolated analog input module specifically engineered for the CENTUM VP Distributed Control System (DCS). This module features integrated intrinsic safety barriers and supports HART communication, allowing the DCS to acquire 4-20 mA process data and digital diagnostic information directly from hazardous area transmitters. By consolidating isolation and communication into a single unit, the ASI533-H00 streamlines your control architecture. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum signal precision and system-wide reliability.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe ASI533-H00 utilizes Yokogawa's specific hardware designation to define its communication and protection capabilities:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eASI533\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Module with Built-In Barrier (8-channel, Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports HART Communication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 0 (Standard Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 0 (Basic Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ASI533-H00 provides high-fidelity analog-to-digital conversion while maintaining strict electrical separation between field and system.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8, fully isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHART (Highway Addressable Remote Transducer).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in intrinsic safety barrier for hazardous area interfacing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Update Period:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms (High-speed scanning).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% of full scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation between channels and to the system backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGuaranteed 100% Brand New and Original.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ASI533-H00 provides targeted technical benefits for complex process integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Intrinsic Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in barrier eliminates the need for external DIN-rail mounted isolators or barriers. This design reduces the physical footprint of the I\/O cabinet by up to 50%, significantly lowering cabinet manufacturing and wiring costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced HART Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module enables the DCS to access secondary variables and device health data from smart field instruments. Maintenance teams can monitor transmitter health or remotely configure devices, drastically reducing the need for manual field inspections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel-to-Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 8 channels operates with full electrical independence. If a field fault or ground loop occurs on one loop, the isolation prevents the disturbance from affecting adjacent channels or the central processor, ensuring localized fault containment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite the overhead of HART data, the module maintains a 10 ms data update cycle. This ensures that the primary 4-20 mA control variable remains responsive and accurate for fast-acting pressure and flow control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the ASI533-H00 with non-HART 4-20 mA transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module supports HART, it functions perfectly with standard analog 4-20 mA devices. The system will simply treat the input as a conventional analog signal if no HART data is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module supply power to the field transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASI533-H00 typically acts as the power source (distributor) for 2-wire transmitters through the intrinsic safety barrier. Please verify your specific terminal board configuration to ensure it matches your loop power requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat hazardous zone ratings does the built-in barrier support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASI533 series is designed to interface with devices in Zone 0, 1, or 2, depending on the system's overall certification. Always check the official Yokogawa \"Instruction Manual\" for the specific entity parameters (Vcc, Isc) to ensure compatibility with your field sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this an original brand-new part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits. Every ASI533-H00 arrives in its original Yokogawa factory box with matching serial numbers and the manufacturer’s original protective seals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52824577638709,"sku":"ASI533-H00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ASD143-P00_9f4acef4-37db-4cf6-a78c-df38fef1ba1c.png?v=1778046832","url":"https:\/\/www.5gplc.com\/products\/yokogawa-asi533-h00-centum-vp-8-channel-isolated-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}