{"product_id":"yokogawa-anb10d-427-cu2n-centum-vp-esb-bus-node-unit","title":"Yokogawa ANB10D-427\/CU2N CENTUM VP ESB Bus Node Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-427\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-availability I\/O expansion hub within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This ESB Bus Node Unit enables the connection of local and remote FIO modules to the Field Control Station (FCS), facilitating high-speed data acquisition and process control. By utilizing a dual-redundant architecture for both communication and power, it maintains uninterrupted signal flow between field instruments and the processor. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control infrastructure meets the highest factory-certified standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ANB10D-427\/CU2N\u003c\/h3\u003e\n\u003cp\u003eYokogawa specifies the functional capabilities of the ANB10D series through the following alphanumeric suffix logic:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant power supply modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 - 240 V AC power supply input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard hardware revision (Updated from legacy 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Unit for ESB Bus (Standard type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-427\/CU2N integrates robust electrical and mechanical parameters to handle heavy I\/O loads:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant ESB Bus (Extended Serial Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e220 V to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant power modules and dual-path bus communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccommodates Yokogawa FIO (Field Input\/Output) modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes \/CU2N Connector Unit for ESB bus interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch rack-mountable (requires 5U height)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-427\/CU2N addresses the core requirements of modern process automation facilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Signal Loss via Bus Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant ESB bus interface provides two independent physical paths for data. If one ESB cable sustains physical damage, the unit maintains 100% process visibility through the secondary path, preventing the loss of critical field data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Power Availability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates a dual-redundant power supply configuration. This allows the unit to draw power from two independent sources. If one power module fails, the healthy module assumes the full load instantly, permitting \"hot-swapping\" or online replacement without interrupting I\/O operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Hardware Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector unit facilitates rapid daisy-chaining of multiple I\/O nodes. This standardized interface reduces wiring errors and ensures stable, high-speed signal transmission across the system backplane, even in cabinets with high-density cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Grid Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically engineered for 220-240V AC environments, the internal power circuitry filters industrial line noise and handles voltage transients typical of large-scale manufacturing grids, protecting sensitive FIO modules from electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the \/CU2N option include an internal terminator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard connector unit without a terminator. If this node occupies the final position in your ESB bus chain, you must use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector unit or install an external terminator to prevent signal reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an ANB10S with this ANB10D model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ANB10D (Duplexed) provides higher reliability than the ANB10S (Single). Ensure your Field Control Station (FCS) features dual-redundant ESB bus ports to utilize the secondary communication channel provided by this unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting hardware does the unit require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit fits standard 19-inch racks. We recommend utilizing the specified M5 screws and insulation bushes to prevent ground loops and ensure the 10 kg chassis remains stable against industrial vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with 110V AC power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The suffix code \"2\" specifically denotes a 220-240V AC input. For 110V AC environments, you must select the model with the \"1\" suffix code to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52761879675189,"sku":"ANB10D-427\/CU2N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ANB10D-427CU2N.png?v=1776666711","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-427-cu2n-centum-vp-esb-bus-node-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}