{"product_id":"yokogawa-anb10d-426-cu2n-ndel-centum-vp-node-unit-for-dual-redundant-esb-bus","title":"Yokogawa ANB10D-426\/CU2N\/NDEL CENTUM VP Node Unit for Dual-Redundant ESB Bus","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-426\/CU2N\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance interface node for the CENTUM VP distributed control system. This unit connects I\/O modules to the Field Control Station (FCS) via a dual-redundant ESB bus, maintaining high-speed data synchronization. Engineered for harsh environments, this specific configuration incorporates G3-level environmental protection and an extended temperature range. We guarantee this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, shipped in factory-sealed packaging.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe suffix and option codes define the specialized hardware capabilities of this ANB10D unit:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEquipped with Dual-Redundant Power Supply modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigured for 220–240 V AC Power Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncludes ISA Standard G3 Conformal Coating \u0026amp; Extended Temp (-20°C to 70°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncludes Connector Unit for ESB Bus (Part No. S9562FA, 2 pieces)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncludes Node Expansion Software License\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis unit meets the following industrial hardware standards:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant 220–240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 70°C (Extended Range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA Standard G3 compliant conformal coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-Redundant ESB Bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2x S9562FA Connector Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Status:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNDEL Node Expansion License included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExplosion Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNone (Basic Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBrand New, Original Yokogawa Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Atmosphere Survival:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe G3-rated conformal coating protects internal circuitry against corrosive gases (such as\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$H_{2}S$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$SO_{2}$\u003c\/span\u003e). This ensures long-term reliability in chemical processing plants or refineries where standard electronics often fail due to terminal corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile standard units fail at 50°C, the \"-6\" option extends the operational threshold from -20°C up to 70°C. This allows for installation in outdoor cabinets or non-climate-controlled environments without risking logic errors or hardware shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Capacity Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elicense enables immediate node expansion within the CENTUM VP architecture. This eliminates the need for post-purchase software upgrades and allows for rapid scaling of I\/O capacity during system commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Availability Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant power architecture ensures that a single power module failure or a tripped circuit breaker does not halt the process. The unit seamlessly draws power from the healthy secondary source to maintain bus communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \/CU2N option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \/CU2N option provides two S9562FA connector units. These connectors facilitate the physical link between the ESB bus cables and the node unit, ensuring low-impedance signal transmission and secure mechanical fastening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this unit in an outdoor cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the enclosure meets the necessary IP rating for moisture and dust. The unit’s -20°C to 70°C rating specifically supports environments with significant temperature fluctuations that would damage standard-grade hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support hot-swapping of power modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe dual-redundant configuration allows you to replace one power supply module while the other remains energized, ensuring the node stays online during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the \/NDEL license already activated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \/NDEL suffix indicates the unit comes with the node expansion software authorization. You should verify your system's total node count within the CENTUM VP software environment during integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52763048804661,"sku":"ANB10D-426\/CU2N\/NDEL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AFV10D-S411012_70882cbe-e5da-4cba-8906-c63c8d5d5e94.jpg?v=1776671403","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-426-cu2n-ndel-centum-vp-node-unit-for-dual-redundant-esb-bus","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}