{"product_id":"yokogawa-anb10d-421-cu2n-ndel-duplicated-node-interface-unit","title":"Yokogawa ANB10D-421\/CU2N\/NDEL Duplicated Node Interface Unit","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"citation-257\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-421\/CU2N\/NDEL\u003c\/strong\u003e\u003cspan class=\"citation-257\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eDuplicated Node Interface Unit (NIU)\u003c\/strong\u003e\u003cspan class=\"citation-257\"\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan class=\"citation-257 citation-end-257\"\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis unit serves as a critical local or remote I\/O subrack, housing up to 8 FIO (Field Input\/Output) modules. The \"D\" designation signifies its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDuplexed (Redundant)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, providing dual paths for power and communication to ensure continuous process monitoring. This specific configuration includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption codes, which define specialized communication connector settings and destination-specific hardware labeling for international standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003ePart Number Breakdown: ANB10D-421\/CU2N\/NDEL\u003c\/h2\u003e\n\u003cp\u003eYokogawa uses a structured coding system to define the NIU's electrical, mounting, and interface properties:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eANB10D:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuplicated Node Interface Unit (for FIO).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant 100-120 V AC Power Supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch Rack-mount type with insulation bushing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard functional hardware type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/CU2N:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication interface option specifying connector types and noise filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/NDEL:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized labeling or destination-specific hardware designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ANB10D-421 provides a robust and redundant electrical environment for high-density I\/O modules.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-256\"\u003e\u003c\/span\u003e\u003cstrong\u003eNumber of I\/O Slots:\u003c\/strong\u003e\u003cspan class=\"citation-256 citation-end-256\"\u003e\u003cspan\u003e \u003c\/span\u003e8 slots (supports Analog, Digital, and Communication FIO modules)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-255\"\u003e\u003c\/span\u003e\u003cstrong\u003eInterface Bus:\u003c\/strong\u003e\u003cspan class=\"citation-255 citation-end-255\"\u003e\u003cspan\u003e \u003c\/span\u003eESB Bus (Extended Serial Backplane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100-120 V AC, 50\/60 Hz (Dual-redundant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan class=\"citation-254 citation-end-254\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch rack-mount (with insulation bushing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC between power terminals and ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 100 VA (at 100-120 V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 50°C (32 to 122°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower units and dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEC401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebus modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ANB10D-421\/CU2N\/NDEL is designed to eliminate single points of failure.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-253 citation-end-253\"\u003eBy utilizing dual-redundant power supplies and ESB bus interfaces, the unit ensures that all 8 I\/O modules remain online and communicating with the Field Control Unit (FCU) even if one power circuit or communication cable fails.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround Loop Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"2\" in the suffix indicates the inclusion of insulation bushings for rack mounting. This physical isolation prevents electrical noise and ground loops from the cabinet frame from interfering with sensitive signals, ensuring high measurement accuracy for analog modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable I\/O Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis NIU allows for the physical distribution of I\/O modules across the plant. By connecting several ANB10D units via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB bus cables, a single controller can manage widely dispersed field points while maintaining high-speed data synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Hardware Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll redundant components, including power supply units and bus interface modules, are hot-swappable. Maintenance teams can replace a faulty component while the system is live and the process is running, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 8 dedicated slots in a 19-inch form factor, the ANB10D maximizes cabinet space efficiency. This allows for a more compact control room footprint while maintaining the heat dissipation necessary for long-term component reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between ANB10D and ANB11D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ANB10D is used for standard ESB Bus (local or near-distance), while the ANB11D is utilized for the Optical ESB Bus, allowing for longer distances between the controller and the I\/O node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I connect the ANB10D-421 to the Field Control Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-252\"\u003eThe NIU connects to the FCU (e.g., AFV30D or AFV10D) using\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eESB Bus Cables\u003c\/strong\u003e\u003cspan class=\"citation-252 citation-end-252\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFor a redundant system, these cables must be used in pairs to maintain the duplicated communication path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include the I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The ANB10D-421\/CU2N\/NDEL is the base chassis and power assembly. You must order specific I\/O modules (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI141\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e) separately based on your project's I\/O requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this unit in a 220V AC environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The suffix \"-4\" indicates a 100-120V AC rating. For 220-240V AC power environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10D-2xx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52472050942261,"sku":"ANB10D-421\/CU2N\/NDEL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AFV10D-S41211_7c420c43-0b63-4641-a60b-7eb819bc516b.jpg?v=1774342355","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-421-cu2n-ndel-duplicated-node-interface-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}